If you check the box "Ring external siren on alarm", an additional line ("Output level") appears.
Here you can set the threshold to "High" or "Low" in the selection box.
Check the box "Alarm mail notification" if you want the device to send an e-mail when the alarm is
triggered.
If you check the box "Upload image when the alarm is triggered", an additional line appears
"Upload intervall (seconds)". Here you can set the intervals at which an image is to be uploaded.
You can set the interval between 0–255 seconds.
If you check the box "Scheduler", the following overview appears:
GB
The weekdays are shown on the vertical axis, the times 0 to 23 hrs on the horizontal axis. Each field
represents a quarter of an hour in which the previously selected alarm functions can be activated.
Click the fields for the time frame within which the alarm is to be triggered if the device registers
motions or audio signals. An activated field is marked blue. Double-clicking on an activated field
selects all the fields of the affected hour.
NOTE
►
The e-mail and upload functions are only available if the camera has a working Internet
connection.
Mail notification settings
If you have checked the box "Alarm mail notification" on the menu page "Alarm settings", you can
enter the e-mail address of the sender as well as the SMTP server and SMTP port to be used under
"Sender's email". Note the corresponding parameters and settings of your e-mail provider.
108
IUK 5 A1