Hedson IRT COMBI 4-1 IR/UVA Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
9.4 Settings
Ch. Overview
9.4.1
1 Select Language
9.4.2
3 Process Alarm
9.4.3
4 Temp Unit
9.4.4
5 Buzzer
9.4.5
7 Basic PIN Code
9.4.6
8 Short Dist lim.
9.4.7
9 Long Dist lim.
9.4.8
15 Temperature Ctrl
9.4.9
16 Disp. Contrast
9.4.10
18 Distance
9.4.11
23 Filter Time
9.4.12
25 Contin. Mode
9.4.13
36 Advanced PIN Code
9.4.14
37 Dist Unit
9.4.15
43 Advanced Code
9.4.16
44 Reset Prog. settings
9.4.17
45 Reset Filter Timer
9.4.18
46 Statistics
9.4.19
47 Perform Self test
9.4.20
48 Program Time Scale
9.4.21
49 Proc. Alarm Temp
9.4.22
53
UV Run time
9.4.1
1 Select Language
Use the up and down arrow keys to scroll through the fourteen
different languages (arranged alphabetically) until the correct
language appears. Press select to confirm.
If you accidently switch to a language that you don´t understand, turn
the main switch on while pressing the "cassette in use" button. The
dryer will then start up with British English.
9.4.2
3 Process Alarm
Use the up and down arrow keys to set whether the alarm is active
or not. Press select to confirm. For alarm sound settings, see "9.4.4
Buzzer".
9.4.3
4 Temp. Unit
°C and °F appear on the screen. Use the up and down
arrow keys to select the desired temperature unit. Confirm the
selected unit by pressing select.
9.4.4
5 Buzzer
The sound effects can be muted/activated by using the
arrow keys to select no/yes. Press select to confirm.
9.4.5
7 Basic PIN Code
You can change the PIN code to prevent unauthorized access to the
basic settings, as described in table in chapter 9.4. To do this use
the up and down arrow keys to change the first digit, press select to
confirm. Continue with the second, third and fourth digit. When
completed press select to confirm the new four digit PIN code.
8
available in
Basic
Advanced
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
GB
9.4.6
8 Short Distance Limit
The original settings for the correct short distance limit is
55 cm. You can change the value for the short distance limit from 35 to
95 cm. Settings higher than 80 cm are not recommended. Press select
to confirm.
9.4.7
9 Long Distance Limit
The orginal settings for the correct long distance limit is
65 cm. You can change the value for the long distance limit from 40
to 130 cm. Settings higher than 100 cm are not recommended. Press
select to confirm.
9.4.8
15 Temperature Ctrl
You can choose if you want to turn the temperature control
(pyrometer) on or off permanently.
Note! If you turn the temperature control off in settings mode you
cannot activate it in program mode.
Temperature graphs and values will not be accessible when this
feature is turned off. Instead the software will work with power levels,
that is percentage of maximum capacity.
9.4.9
16 Disp. Contrast
You can change the contrast of the display on a scale from light to
dark (25–55). Scroll between the values with the up and down arrow
keys and press select to confirm.
9.4.10 18 Distance
You can change the distance measuring between centimeters and
text. If text is choosen the distance is indicated on the display as
"too close", "too far" or "correct". If measuring fails "check distance
manually" appears.
9.4.11 23 Filter Time
The default value is 400 working hours. After this time, the filter
replacement warning is displayed for filter change. If the mobile dryer
is placed in a dusty environment, it is recommended to change more
frequently.
Note! Keep in mind that if the filter is too dirty, the lamp service life
will be reduced as a result of impaired cooling. To reset, see "9.4.17
Reset filter timer".
9.4.12 25 Contin. Mode
The continuous mode is for sales demo purposes.
For safety reasons and for minimizing unnecessary wearing down of
the dryer, this mode must only be used in exceptional cases.
9.4.13 36 Advanced Pin Code
To change the code to your personal choice use the up and down
arrow keys to change the first digit, press select to confirm. Continue
with the second, third and fourth digit. When completed press select
to confirm the new four digit PIN code.
Warning! Make sure that you remember the new code.
9.4.14 37 Dist Unit
This provides you with the opportunity to change unit type between
centimeters and inches.
9.4.15 43 Advanced Code
It is possible to enable/disable the request for a PIN code. This will
remove the PIN code request in program mode and the code 0000
will give you access to advanced settings.
Press select to confirm your choice.
9.4.16 44 Reset Prog. settings
You can reset to the pre-programmed factory settings for all
programs. Confirm by pressing yes.
714812 rev 2

Publicité

Table des Matières
loading