5.

Application

PROTRONIC-C A3000 open non-touch, opto-electronically controlled washbasin
mixer DN 15. Design with temperature-selector lever. With facility for externally
controlling options such as fittings settings and communication via ECC function
controller. Adjustable flow duration, down to the second.
2000101161 ... for connection to hot and cold water supplies
2000101162 ... for connection to pre-mixed warm water or cold water supplies
Control functions:
– Hygiene flushing (10 seconds), 24 hours after last usage
– Safety switch-off when there is continuous reflection
Additional functions with ECC function controller (Ethernet):
– Automatic thermal disinfection according to DVGW work sheet W 551 as well
as safety switch-off
– Cleaning switch-off
6.

Technical Specifications

Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculation flow rate:
2000101161
2000101162
Volumetric flow:
Operating voltage:
Power consumption:
Communication:
Type of protection:
1.0 bar
1–5 bar
10 bar
0,07 l/s
0,07 l/s
0.10 l/s
0.10 l/s for 3 bar flow pressure
24 V DC
2.5 W
Ethernet via ECC function controller
IP 68