The product must be installed only by qualified persons, according to the local safety standards and
regulations. It is classified as Class II, in accordance with EN 60065 and, for this reason, it shall not be
connect to the protective earth (PE) of the supply mains.
Installation warnings
•
Use only the original power cable, installing the product so that the mains plug is easily accessible.
•
The product must not be exposed to dripping or splashing and thus it shall be installed indoors, in a dry
place.
•
Don't install the product above or close to heat sources, in dusty places or where it might come into
contact with corrosive substances.
•
Leave some space around the product housing (at least 8 cm over and under) to ensure sufficient
ventilation; an excessive operating temperature and/or an excessive heating may affect the performance
and the life of the product
•
To prevent injury, this product must be securely attached to the wall, on the floor or in a rack in accordance
with the mounting instructions given on Chapter 2. PRODUCT INSTALLATION.
In accordance with the European Directive 2004/108/EC (EMC), the product shall be installed using devices,
cables and connectors that allow to comply with this directive requirements for fixed installations.
Fracarro Radioindustrie SpA is not responsible for the possible network diffusion of the television signal
decoded by SIG9808CI. The installer and the product user must follow the user conditions provided by the
service provider and those specified in the purchasing agreement of the "smart card".
Therefore, Fracarro Radioindustrie SpA is relieved from any civil or criminal responsibilities due to a breach
of juridical regulations in the matter and arising from any improper use performed by the installer, by the user
or by third parties.
Earthing of the antenna system
The product must be connected to the earth electrode of the antenna system, in accordance with standard EN
50083-1, section 10. The screw to be used for this scope is marked with the symbol
to follow the provisions of EN 50083-1 and not to connect the screw to the protective earth (PE) of the supply
mains.
IMPORTANT: Open the panel only for audio and video regulation and for insertion and removal of the CAM
modules or the single receivers; therefore, never do any operation on the internal circuits of the product and,
in particular, never remove the metal cover, which protects the main power supply section (left side), to avoid
the access to hazardous voltage parts. Only instructed and authorized persons can open the product. In case
of failure, do not try to repair the product; otherwise the guarantee will no longer be valid.
The headend has to be installed by using the supplied brackets and screws. Take the assembling brackets
out from the package and pull the headend out. Some holes are present on the filling cardboard to show the
position of the bracket holes. This cardboard can be used to mark the position on the wall where drilling the
holes for the screws. Install the brackets by referring to Figure 3, if the unit will be installed on the floor; refer
to Figure 4, if the unit is installed on the wall. Leave a little space to disconnect the supply cable and open
the front panel.
It is also possible to install the headend on the 19" rack cabinets (see Fig. 5); refer to Fracarro catalogue for
any further relevant information and cabinet size.
In order to allow the air-cooling through natural convection it's recommended to insert the headend as shown
in figure 3,4,5 and then allow the air to pass through, from the bottom to the top.
NOTE: we recommend to take note of the key code on the front panel in the event that the key is lost.
1. SAFETY WARNINGS
2. PRODUCT INSTALLATION
21
. It is recommended