2.11 7-pole fan plug connector
Procedure
Connect the two 7-pole plus for the fan connection.
Open the plug retainer on the 7-pole plug (fan) of the hob
and attach the 7-pole fan mating connector (e) until it is
securely engaged. Then close the plug retainer again.
After installation, fi t the connectors on the rear panel or in
the shelf unit.
e
2.12 4-pole plasma fi lter plug connector (optional)
Procedure
Open the plug connections on the 4-pole plug (plasma) of
the hob and remove the protective covers. Attach the plug
to the 4-pole mating plug of the plasma fi lter (g) until it has
fi rmly engaged.
Then close the plug retainer again.
After installation, fi t the connectors on the rear panel or in
the shelf unit.
h
Instructions for assembly
•
The electrical connection must be carried out by a
qualifi ed electrician who is authorised to carry out such
work!
•
Statutory regulations and the connection specifi cations
issued by the local power supply company must be
strictly observed.
•
When connecting the appliance it must be ensured that
there is a device which makes it possible to universally
disconnect it from the mains with a contact opening
width of at least 3mm. Line-protecting switches, fuses
or contactors are suitable cut-out devices. When
connecting and repairing the appliance disconnect it
from the electricity supply with one of these devices.
•
The earth wire must be suffi ciently long so that if the
strain relief fails, the live wires of the connecting cable
are subjected to tension before the earth wire.
•
Any superfl uous cable must be removed from the ins-
tallation area beneath the appliance.
•
Make sure that the local mains voltage is the same as
the voltage on the rating label.
•
Full protection against accidental contact must be en-
sured on installation.
•
Attention: Incorrect connection may result in the power
electronics unit being destroyed.
•
The appliance is only authorised for permanent
connection. It may not be connected with a shock-proof
plug.
WARNING OF ELECTRICAL ENERGY!
RISK OF FATAL INJURY!
Live components have been installed
near this symbol. Covers bearing this sign
may only be removed by a certifi ed skilled
electrician.
GB
39