Programming a saturated carbon filter (Caution: carry out the programming with the motor disabled):
Operation: Simultaneously press + and – for 5 sec. until the red LED flashes 3 times.
• The run-out time has now been set to 30 minutes (instead of 10 min.).
• The saturated carbon filter indicator has been set (200 operating hours).
The red LED will light up after 200 working hours (time to regenerate the Monoblock).
Reprogramme: simultaneously press + and – for 5 sec. until the red LED flashes 3 times for confirmation. (if this
programming is not carried out, the programming is automatically set after the device has been switched on 10 times.)
Disable the programming: Simultaneously press + and – for 5 sec. until the third green LED flashes 3 times.
Clean the monoblock filter:
• The Monoblock filter can be regenerated up to 12 times. This is carried out in the oven.
• Place the filter in the oven for 1 hour at 120°C. Provide sufficient fresh air in the room where the oven has been
placed, as smells can be released.
• Smells can be released when baking certain kinds of fish. The best solution is to immediately regenerate the filter.
NOVY nv behoudt zich het recht voor te allen tijde en zonder voorbehoud de constructie en de prijzen van haar producten te wijzigen.
NOVY SA se réserve le droit de modifier en tout temps et sans préavis la construction et les prix de ses produits.
Die NOVY AG behält sich das Recht vor, zu jeder Zeit und ohne Vorbehalt die Konstruktion und die Preise ihrer Produkte zu ändern.
NOVY nv reserves the right at any time and without reservation to change the structure and the prices of its products.
NOVY nv
Noordlaan 6
B - 8520 KUURNE
Tel. 056/36.51.00 - Fax 056/35.32.51
E-mail : novy@novy.be
http://www.novy.be
France: Tél: 0320.940662
Deutschland und Österreich: Tel: +49 (0)511.54.20.771
ref M 7300400 E