1. Safety instructions

For skilled electricians and instructed person-
nel in accordance with national legislation, in-
cluding the relevant standards and, where ap-
plicable, in acc. with IEC 60079-17 on electrical
apparatus for explosive atmospheres.
The light fitting must not be operated in zone
0,1,2 or 20,21 hazardous areas!
The technical data indicated on the light fitting
are to be observed!
The requirements of the EN 61241-0 and -1
regarding excessive dust deposits and
temperature to be considered from the user.
Changes of the design and modifications to the
light fitting are not permitted!
The light fitting shall be operated as intended
and only in undamaged and perfect condition!
Only genuine CEAG/Cooper Crouse-Hinds
GmbH (CCH) spare parts may be used for
replacement!
Repairs that affect the explosion protection (see
national standard), may only be carried out by
CEAG/CCH or a qualified "electrician"!
Do not keep these operating instructions
inside the light fitting during operation!
The national safety rules and regulations for
prevention of accidents and the following
safety instructions which are marked with
an (
) in these operating instruction, will
have to be observed!
Address
Address
switch 1
switch 2
0
0
0
1
0
2
...
...
1
0
1
1
...
...
...
...
2
0
2
1
...
...
9
9
Fig. 4 Addressing
Cooper Crouse-Hinds GmbH
4
2. Conformity with standards
The light fitting is suitable for use in zone 22
hazardous areas acc. to EN 61241-0.
It has been designed, manufactured and tested
according to the state of the art and according to EN
ISO 9001:2000.

3. Technical data

EC type examination
certificate:
Category of application
aacd 94/9/EC.:
Protection acc to 60529:
Rated voltage AC:
D22 EXIT 24 V
D22 EXIT
D22 EXIT CG-S
Rated voltage DC:
D22 EXIT
D22 EXIT
D22 EXIT CG-S
Rated frequency
Rated current
110 V AC/DC:
230 V AC/DC:
Insulation class
to EN 61140:
Supply terminal clamping capacity
2 x per terminal:
Ex-e cable entry
standard version:
metal thread:
Test torque for M 20 x 1.5
cable entry:
Test torque for pressure
screw:
(for sealing off the cable or the blanking plug)
4. Installation D22 EXIT
The respective national regulations as well as the
Luminaire
general rules of engineering which apply to the
address
installation and operation of explosion protected
Monitoring off
apparatus will have to be observed!
1
Transport and storage of the luminaire is permitted
2
in original packing and specified position only!
...
10
Opening and closing the light fitting
11
Unscrew the four recessed head screws of the
...
cover
...
Remove the protective cover. If putting
20
down take care to prevent scratches on the silk
not permissable
screen cover
Installation of the fitting
not permissable
The luminaire shall be fitted by using the four
mounting clips with suitable fixing screws
(Ø: 5 mm, fig. 1) onto a suitable surface.
Mains connection
After opening the cover unscrew the screw (allen
screw 4 mm) of the LED-printed board (fig.1). The
printed board can be swiveled out.
Pass the cable (5.5 to 13 mm) through the certified
EEx cable entry M 20 x 1,5. Use both sealing inserts
for cables from 5.5 to 8 mm, and the outer sealing
insert only for cables from 8 to 13 mm. Pay attention
to the proper fit of the remaining sealing insert in the
certified cable gland.
In case of unused cable entries, remove their
protective cover and close the entries with a blanking
plug (torque of 2.5 Nm). When closing the gland with
a blanking plug, always use both sealing inserts!
When metal cable entries are used, the protective
caps of the unused entries are to be removed and
the entries to be closed with certified EEx blanking
plugs!
Attention!
Only fix laid cable may be used for connection!
If cable glands from other manufacturer are used
the instructions regarding strain relief and clamping
capacity must be observed!
Connect the conductors to the terminals L, N
and PE in accordance with the terminal marking
(see fig. 2).
Remont the LED-printed board into the housing.
Take care not to pinch any conductors. Install
the protective cover with the four screws.
Tighten the screws only hand-tight!
5. Monitoring (only D22 EXIT CG-S)
The CG-S module monitors and indicates to the
connected CEAG emergency supply system the
operation of the supply unit circuit and the function
of min. 50 % of the installed LEDs.
The CG-S module allows single monitoring of these
luminaires in CEAG emergency lighting systems. The
switching mode (maintained/non-maintained and
switched emergency luminaires) is freely program-
mable and mixed operation up to 20 addresses in a
BVS 07 ATEX E 131
single circuit is possible.
II 3D Ex tD A22 IP 66 T80 °C
Addressing
IP66
Before fitting the cover, the addressing of the
non-permissible
individual luminaires is to be carried out. The desired
110 V - 277 V
address (fig.4, 1 - 20) is set on the address switch by
220 V - 254 V
means of a suitable screw driver (Arrowhead to No.,
fig. 3). If the luminaire should not be monitored the
12 - 24 V DC ± 20%
code 0/0 has to be selected.
110 V - 250 V ± 10%
The standing luminaire D22 EXIT and is not equipped
195 V - 250 V ± 10%
with monitoring circuit and can not be addressed.
50 - 60 Hz
6. Taking into operation
0.05 A
Prior to operation, check the light fitting for its
0.025 A
proper functioning and installation in compliance with
these operating instructions and other applicable
I
regulations!
Only carry out insulation measurements between PE
3 x 2.5 mm²
and the external conductor L1 as well as between
M20x1,5 for cable
Ø 5,5 to 13 mm
M20x1.5
3.75 Nm
2.5 Nm
the maintenance, servicing and test of apparatus for
explosive atmospheres e.g
EN 60079-17 as well as the general rules of
engineering!
Repair
Prior to replacing or removing any components,
observe the following:
Cut the apparatus off the voltage before opening
it or carrying out repairs! Only use certified
genuine CEAG/CCH spare parts! (See CEAG/CCH
spare parts list).
Subject to alteration or supplement of this prod-
uct series.
Regarding waste disposal, observe the relevant
national regulations! The plastic materials are
marked with material identifications.
PE and N.
– measuring voltage: max. 1 kV AC/DC
– measuring current: max. 10 mA
Mind: There must no insulation measurement be
carried out between L and N, since that would
destroy the electronics (mains input fuse in the
unit).
7. Maintenance
Observe the national regulations applicable to
Servicing
When servicing, in particular those components
that affect the explosion protection, will have to
be checked, e. g.:
Housing and protective bowl for any cracks
or damages.
Gaskets for their perfect condition.
Terminals and blanking plugs for their firm fit.
Because of the risk of an electrostatic charge, the
light fitting shall only be cleaned with a damp,
non-fibrous cloth or sponge!
Only use customary household washing-up liquid
diluted in water as specified! The water tempera-
ture may be max. 50°C.
After that, rinse with clear water to prevent the
risk of tension cracks in the protective bowl!