IMPORTANT:
•
Do not connect auxiliary relays or other devices tot he 18 V DC output (terminals 11 – 12) to
avoid malfunctions of the control unit. Use separated power supply / transformers instead;
•
do not connect switching feeders or similar apparatus close to the barrier that may be a
source of disturbance;
LOGIC ADJUSTMENTS
Make the logic adjustments.
Note: when any adjusting devices (trimmers or dip-switches) on the control panel are operated,
a complete manoeuvre must be carried out in order for the new settings to take effect.
TRIMMER
T.R.A.
not used;
T.C.A.
Automatic Closing time adjustment: from about 0,1 to 12 seconds (see dip-switch
no. 1);
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor
to obstacles diminishes and therefore the thrust force increases; vice-versa, by
rotating it counter-clockwise, the sensitivity of the gearmotor to obstacles
increases and therefore the thrust force diminishes.
Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
CLOSES AGAIN
3
AFTER THE
PHOTOCELL
4
NO REVERSE
PRE-
5
FLASHING
6
FOTOTEST
MASTER/
7
SLAVE
BAR
8
LED
when completely open, closure is automatic after the set time on the
On
T.C.A. trimmer has past.
Off
the closing manoeuvre requires a manual command.
when the automation is operating, a sequence of opening/closing com-
On
mands causes the bar to OPEN-CLOSE-OPEN-CLOSE, etc.
in the same conditions, the same sequence of commands causes the
Off
bar to OPEN-STOP-CLOSE-STOP-OPEN-STOP, etc . (step-by step
function) (see also dip switch
after the photocell is activated (input 7 - 9), the automation closes
On
automatically after 1 seconds.
Off
function off.
the automation ignores the closure command during opening and auto-
On
close time.
Off
the automation responds as established by dip switch No. 2.
On
the pre-flashing function is enabled.
Off
the pre-flashing function is disabled.
On
the "photocell test" function is enabled.
the "photocell test" function is disabled.
Off
Note: to be used when the photocells are not used.
enables the MASTER mode in the master/slave configuration (see T-
On
COMM instructions).
enables the SLAVE mode in the master/slave configuration (see T-
Off
COMM instructions), or standard operation (single motor).
On
when the boom is lifted all LEDs remain OFF.
when the boom is lifted all LEDs behave as per setting of wire terminals
Off
16-18 (default: FLASHING).
K206MA
4).
19