Glass Replacement - Evo SG Manuel D'installation Et De Fonctionnement

Meuble réfrigéré vertical
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION AND OPERATION GUIDE
0 _MAINTENANCE —WASTE MANAGEMENT—DISPOSAL OF MATERIALS
5.
All maintenance operations and repairs must be carried out with the unit in stop position
and with the power of the unit and of the condenser unit switched off.
These maintenance operations must only be carried out by specialised qualified staff.
Wear protective gloves
5_1_______PERIODIC CHECKS
The unit must be checked at least twice a year by qualified staff in order to verify the correct op-
eration of the system; the following must be verified:
the condensed water drainage system must work correctly
check for gas refrigerant leaks and make sure the refrigeration unit works correctly
make sure the condition of the electric system is completely safe
check the rear sliding doors gaskets as well as the door itself and make sure it closes cor-
rectly
clean the condenser of the refrigeration unit
The lifeline of the front glass is carefullyset
5_2

GLASS REPLACEMENT

In case of replacement or damage of the front of glass / side glass / shelf glass, do not dissipate
them on the environment.
In case of damage and / or replacement of the front glass / glass hand side shoulder of
the window, retrieve the shards of glasswithout dispersing into the environment, pay atten-
tion, after the breakage of the glass by manipulating the same care to avoid cutting yourself.
The front glass must be raised and accompanied and handled with care to reach the position of
maximum opening and held open only for the time strictly necessary for the operations of
discharge and Unloading of goods and/or cleaning.
Warning note:
During the opening and closing the front glass, do not hit the glass, handle it with care, in nor-
mal operation, the glass remains in the closed position.
Remember that the safety wire the front glass is fixed thoroughly
5_3_______REPLACE OF TOP CANOPY AND SHELVES LIGHTINGS
The fluorescent lamps, include the information that the lamps have to be replace by iden-
tical lamps only. See the max lamps power identification label near the lamps.
The electric power supply must be switch-off, by disconnecting the counter or by opening the
switch You find at the top of principal electric supplier whenever it is necessary to change the
lamps. To remove the lamp take the plastic protection of the lamp off and size it at the two
ends. Replace the lamp paying attention not to break it. Install the new lamp following the same
instructions and cover it again with the protection.
.