Safety Instructions; Conformity With Standards; Field Of Application; Application/Properties - Eaton CROUSE-HINDS GHG 516 Série Mode D'emploi

Fiches et prises de 16 a, à 3 pôles, 4 pôles, 5 pôles, pour atmosphères explosives
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dimensions in mm
X = fixing dimensions
Coupler 3-pole
Coupler 4-pole
Coupler 5-pole
Flange socket 3-pole
Flange socket 4-pole
Flange socket 5-pole
4 / 5-pole
Drilling template for flange sockets
8
Explosion protected plug and socket system 16 A,
3-pole, 4-pole, 5-pole, GHG 516
2

Safety instructions

Target group:
For skilled electricians and qualified
personnel in accordance with
national legislation, including the relevant
standards and, where applicable, in acc.
with IEC/EN 60079-14 on electrical appara-
tus for explosive atmospheres.
The GHG 516 plugs and sockets are not
suitable for zone 0 and zone 1 hazardous
areas.
The temperature class and explosion group
marked on the apparatus shall be observed.
Modifications to the plugs and sockets or
changes of their design are not permitted.
They shall be used for their intended
purpose and in perfect and clean condition.
Prior to taking the plugs and sockets into
operation, they will have to be checked in
accordance with the instruction as per section 6.
The sockets may only be used with the
associated COOPER CROUSE-HINDS / CEAG
plugs in undamaged condition.
The interlocking switch of the socket is
mechanically secured by means of
spring-loaded locking pins and cannot be
connected without plug.
Observe the national safety rules and
regulations for prevention of accidents as
well as the safety instructions included in
these operating instructions and set in
italics the same as this text!
3

Conformity with standards

The apparatus are conform to the standards
specified in the EC-Declaration of conformity,
enclosed separately.
References to standards and directives in these
operating instructions always relate to the latest
version. Other additions (e.g. details relating to
the year) shall be observed.
3-pole
4

Field of application

The plugs and sockets GHG 516 are suitable
for use in Zone 2 hazardous areas acc. to
IEC/EN 60079-10-1!
The enclosure materials employed, including
the exterior metal parts, are made of high-quali-
ty materials which ensure a corrosion protec-
tion and resistance to chemical substances
corresponding to the requirements in a "normal
industrial atmosphere
- impact resistant polyamide
- glass-fibre reinforced polyester
- special steel AISI 316 L
In case of use in an extremely aggressive
atmosphere, you can obtain information
concerning the chemical resistance of the
materials used from your
Cooper Crouse-Hinds branch.
5

Application/Properties

The GHG 516 plugs and sockets are used for
the power supply of local controls with varying
locations, as well as of electrical installations,
mobile machinery and driving gear in hazardous
areas.
The low-voltage plugs and sockets GHG 516 are
fitted with a load switch and can be used up to
max. 16 A (see technical data).
The plugs and sockets can generally be used
for the voltage range laid down in IEC/EN 60309
(e.g. U
400V that corresponds to the voltage
N
range 380-415V).
The apparatus connected to the plug shall
be suitable for the applied mains voltage.
In order to switch on the socket, the plug is
inserted, pushed fully home and then turned
through approx. 45° to the right. Thereby the
plug is locked in the socket (see page 9, fig. 1).
For switching off and pulling the plug, proceed
in inverse order.
After separating the plug from the socket, the
latter shall be closed with the hinged cover and
secured with the bayonet ring.
The plug can be pushed into the socket and pulled
out of it only whilst the socket is switched off.
In order to ensure the socket's type of
protection acc. to the type label also with the
plug being inserted, the bayonet ring of the plug
(page 9, fig. 2, item 2) is turned to its stop onto
the socket.
The data as per point 3 and 4 will have to
be taken into account with the use.
Applications other than described are not
permitted without COOPER CROUSE-HINDS
/ CEAG's prior written consent.
For the operation, the instructions stated in
section 7 of the operating instructions will
have to be observed.