Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

27" (68.6 CM) AND 30" (76.2 CM) ELECTRIC SINGLE AND
INSTRUCTIONS D'INSTALLATION
27" (68,6 CM) ET 30" (76,2 CM) - SIMPLE ET DOUBLE
BUILT-IN OVEN SAFETY ................................................................2
INSTALLATION REQUIREMENTS .................................................3
Tools and Parts .............................................................................3
Location Requirements ................................................................3
Electrical Requirements ...............................................................6
INSTALLATION INSTRUCTIONS ...................................................7
Prepare Built-In Oven ...................................................................7
Remove Oven Door(s) ..................................................................7
Replace Oven Door(s) ..................................................................7
Make Electrical Connection .......................................................13
Install Oven .................................................................................14
for Ovens Installed above Warming Drawers) ...........................15
Complete Installation .................................................................16
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT:
À conserver pour consultation par l'inspecteur local des installations électriques.
W11235621A
INSTALLATION INSTRUCTIONS
DOUBLE BUILT-IN OVEN
FOUR ÉLECTRIQUE ENCASTRÉ
Table of Contents/Table des matières
SÉCURITÉ DE LA TABLE DE CUISSON .....................................17
EXIGENCES D'INSTALLATION ...................................................17
Outillage et pièces ......................................................................17
Exigences d'emplacement .........................................................17
Spécifications électriques ..........................................................20
INSTRUCTIONS D'INSTALLATION .............................................21
Préparation du four encastré .....................................................21
Dépose de la/des porte(s) du four .............................................21
Réinstallation de la/des porte(s) du four ....................................22
Raccordement électrique ...........................................................27
Installation du four ......................................................................28
installés au-dessus d'un tiroir-réchaud) .....................................30
Achever l'installation ..................................................................30

Publicité

Table des Matières
loading

Sommaire des Matières pour Jennair JJW2430I

  • Page 1: Table Des Matières

    INSTALLATION INSTRUCTIONS 27" (68.6 CM) AND 30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN INSTRUCTIONS D’INSTALLATION FOUR ÉLECTRIQUE ENCASTRÉ 27" (68,6 CM) ET 30" (76,2 CM) - SIMPLE ET DOUBLE Table of Contents/Table des matières BUILT-IN OVEN SAFETY ..............2 SÉCURITÉ...
  • Page 2: Built-In Oven Safety

    BUILT-IN OVEN SAFETY...
  • Page 3: Installation Requirements

    INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Read and follow the instructions provided with any tools listed Cabinet opening dimensions that are shown must be used. ■...
  • Page 4: Product Dimensions - Single Ovens

    Single Ovens Installed in Cabinet Product Dimensions - Single Ovens 27" (68.6 cm) models 30" (76.2 cm) models A. 29 ⁄ " (75.8 cm) max. overall A. 29 ⁄ " (75.8 cm) max. overall height height B. 27" (68.6 cm) overall width B.
  • Page 5: Product Dimensions - Double Ovens

    Product Dimensions - Double Ovens Cabinet Dimensions - Double Ovens Double Ovens Installed in Cabinet 27" (68.6 cm) models 30" (76.2 cm) models A. 52³⁄ " (133 cm) max. overall A. 52³⁄ " (133 cm) max. overall height height B. 27" (68.6 cm) overall width B.
  • Page 6: Electrical Connection

    Oven must be connected to the proper electrical voltage and ■ For power requirements for models JJW2430I, JJW2427I, frequency as specified on the model/serial/rating plate. The JJW2830I, and JJW2827I refer to the following table.
  • Page 7: Installation Instructions

    INSTALLATION INSTRUCTIONS Prepare Built-In Oven 4. Partially close the door to engage the door latch locks. The door will stop at this point. 1. Decide on the final location for the oven. Avoid drilling or cutting into house wiring during installation. WARNING Excessive Weight Hazard Use two or more people to move and install oven.
  • Page 8: Positioning Oven Feet For Multiple Cabinet Cutout Heights

    3. At a 45° angle, align door hinges with slots in the lower Positioning Oven Feet for Multiple front of the oven cavity. Slowly insert door, making sure you maintain the 45° angle. You will know the Cabinet Cutout Heights door is engaged in the slot when you feel a slight drop.
  • Page 9 2. Remove the foot from the right front spacer by removing the Cutout Height Is Between 28¹¹⁄ " and 29 ⁄ " #8-18 x 3/8" (9.5 mm) screw. (72.8 cm and 74.8 cm) NOTE: Do not remove the spacer. 1. Using 2 or more people, place the oven on its back on a covered surface.
  • Page 10 6. Using 2 or more people, place the oven in its upright Double Ovens position. The positioning of the oven feet allow a double oven to be installed in a cutout height between 48 " and 52³⁄ " (124.1 cm and 132.6 cm).
  • Page 11 4. Install a front foot on the left front spacer using a Cutout Height Is Between 50½" and 51¹⁄ " #8-18 x 3/8" (9.5 mm) screw. (128.2 cm and 129.9 cm) NOTE: Position the foot, so the long side of the foot is facing 1.
  • Page 12 5. In the same manner, install a front foot on the right front Cutout Height Is Between 51³⁄ " and 52³⁄ " of the oven. (130 cm and 132.6 cm) 6. Using 2 or more people, place the oven in its upright 1.
  • Page 13: Make Electrical Connection

    Make Electrical Connection For Double Ovens For Single Ovens WARNING WARNING Electrical Shock Hazard Electrical Shock Hazard Disconnect power before servicing. Disconnect power before servicing. Use 12 gauge copper wire. Use 8 gauge copper wire. Electrically ground oven. Electrically ground oven. Failure to follow these instructions can result in death, Failure to follow these instructions can result in death, fire, or electrical shock.
  • Page 14: Install Oven

    2. Push against the seal area of the front frame to push the 3-Wire Cable from Home Power Supply - U.S. Only oven into the cabinet until the back surface of the front frame touches the front wall of the cabinet. IMPORTANT: Use the 3-wire cable from home power supply where local codes permit a 3-wire connection.
  • Page 15: Install Warming Drawer Deflector Kit (Only For Ovens Installed Above Warming Drawers)

    5. The bottom vent and bottom vent trim (required when Align vent tab (B) with oven frame (A) as shown. ■ the oven is installed with the feet in the tall position) Using one #8-18 x 3/8" (9.5 mm) screw (E) on each side ■...
  • Page 16: Complete Installation

    Install Deflector Kit Complete Installation 1. Flex the upper vent piece (C) away from the lower vent piece (D) to slide the warming drawer deflector (B) between them. 1. Check that all parts are now installed. If there is an extra Some force may be required to flex the upper vent trim (C) part, go back through the steps to see which step was away from the lower vent trim (D).
  • Page 17: Sécurité De La Table De Cuisson

    SÉCURITÉ DE LA TABLE DE CUISSON EXIGENCES D’INSTALLATION Outillage et pièces Pièces fournies Vis n° 8-14 x 1" (2,54 cm) - four simple (2), four double (4) Rassembler les outils et composants nécessaires avant ■ d’entreprendre l’installation. Lire et observer les instructions Vis n°...
  • Page 18: Installation Sous Un Comptoir (Avec Table De Cuisson Installée Au-Dessus)

    REMARQUE : Pour l’installation sous un plan de travail, Dimensions du placard - Fours simples on recommande que le boîtier de connexion soit situé dans le placard adjacent, à droite ou à gauche. Dans le cas de Four simple sous le plan de travail (sans table l’installation du boîtier de connexion sur le mur arrière, de cuisson au-dessus) derrière le four, le boîtier de connexion doit être encastré...
  • Page 19: Fours Simples Installés Dans Un Placard

    Fours simples installés dans un placard Dimensions du produit - Fours doubles Modèles de 27" (68,6 cm) Modèles de 30" (76,2 cm) A. Largeur du placard A. Largeur du placard 30" 27" (68,6 cm) min. (76,2 cm) min. Modèles de 27" (68,6 cm) Modèles de 30"...
  • Page 20: Dimensions Du Placard - Fours Doubles

    Dimensions du placard - Fours doubles Spécifications électriques Si on utilise un conducteur distinct de liaison à la terre lorsque Fours doubles installés dans un placard les codes le permettent, il est recommandé qu’un électricien qualifié vérifie que la liaison à la terre et le calibre pour fils sont conformes aux codes locaux.
  • Page 21: Instructions D'installation

    Pour connaître les spécifications de puissance pour les modèles (avec conducteur de liaison à la terre). Voir la section JJW2430I, JJW2427I, JJW2830I, et JJW2827I, se référer au “Raccordement électrique”. tableau suivant. Le câble blindé flexible du four doit être connecté...
  • Page 22: Réinstallation De La/Des Porte(S) Du Four

    4. Fermer partiellement la porte pour engager les loquets de la Réinstallation de la/des porte(s) gâche de porte. La porte restera bloquée à cette position. du four 1. Saisir les bords latéraux de la porte par le milieu avec les deux mains.
  • Page 23: Positionnement Des Pieds Du Four Pour Des Ouvertures D'encastrement De Hauteur Différente

    5. Identifier les loquets de charnière de la porte du four dans La hauteur de la cavité d’encastrement est comprise les angles de la porte; faire pivoter les loquets de charnière entre 26 " et 27 " (68,4 cm et 70,3 cm) vers la cavité...
  • Page 24 6. À l’aide d’au moins deux personnes, placer le four en La hauteur de la cavité d’encastrement est comprise position verticale. entre 28 " et 29 " (72,8 cm et 74,8 cm) 1. À l’aide d’au moins 2 personnes, placer le four sur sa partie arrière, sur une surface couverte.
  • Page 25 6. À l’aide d’au moins 2 personnes, placer le four en position La hauteur de la cavité d’encastrement est comprise verticale. entre 50½" et 51 " (128,2 cm et 129,9 cm) 1. À l’aide d’au moins 2 personnes, placer le four sur sa partie arrière, sur une surface couverte.
  • Page 26 2. Installer un pied sur la cale d’espacement arrière gauche 6. À l’aide d’au moins 2 personnes, placer le four avec une vis n° 8-18 x 3/8" (9,5 mm). en position verticale. REMARQUE : Positionner le pied de façon à ce que le côté court du pied soit orienté...
  • Page 27: Raccordement Électrique

    Raccordement électrique Fours doubles Fours simples AVERTISSEMENT AVERTISSEMENT Risque de choc électrique Risque de choc électrique Déconnecter la source de courant électrique avant Déconnecter la source de courant électrique avant l'entretien. d'entreprendre le travail. Utiliser du fil en cuivre de calibre 8. Utiliser du fil en cuivre de calibre 12.
  • Page 28: Câble À 4 Conducteurs Depuis L'alimentation Électrique Du Domicile

    Câble à 4 conducteurs depuis l’alimentation Câble à 3 conducteurs depuis l’alimentation électrique du domicile électrique du domicile – É.-U. seulement IMPORTANT : Utiliser le câble à 4 conducteurs provenant du IMPORTANT : Utiliser le câble à 3 conducteurs depuis le point point de distribution du domicile aux États-Unis lorsque les de distribution du domicile lorsque les codes locaux autorisent codes locaux ne permettent pas la mise à...
  • Page 29 4. Retirer le ruban de la garniture noire avant, ainsi que les 6. Pour les modèles dont les pieds sont installés en position attaches de plastiques de l’espaceur d’installation. haute, la garniture de l’évent inférieur doit également être installée. Pour l’installation, procéder selon les instructions Fixer solidement le four au placard à...
  • Page 30: Installation De L'ensemble De Déflecteur Du Tiroir-Réchaud (Uniquement Pour Les Fours Installés Au-Dessus D'un Tiroir-Réchaud)

    10. Répéter cette procédure pour la porte du four inférieur. 3. Aligner le support de l’évent (B) avec le châssis du four (A) comme illustré. 11. Reconnecter la source de courant électrique. 4. Avec une vis n° 8-18 x 3/8" (9,5 mm) (E) pour chaque côté du 12.
  • Page 31: Remarques

    Remarques...
  • Page 32 ® /™ ©2018 JennAir. All rights reserved. Used under license in Canada. W11235621A 10/18 Tous droits réservés. Utilisée sous licence au Canada.

Ce manuel est également adapté pour:

Jjw2427iJjw2830iJjw2827i

Table des Matières