Essential Safety Instructions; General Safety Instructions; Predictable Misuses; Installation, Electrical Connection - Maico EAQ 10/1 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB

5. Essential safety instructions

General safety instructions

● Read the mounting instructions through
carefully before starting up.
● Keep the instructions.
● The device must not be used as a toy.
● Before removing the cover, disconnect the
unit from the power supply (switch off
mains fuse).
● Installation, electrical connections,
starting up and repairs only permitted
when carried out by trained specialists.
● Only connect the unit to a permanent
electrical installation.
– Permitted cable cross section: 1.5 mm².
– Mains isolation device required with
contact openings of at least 3 mm at
each pole.
● The fan unit may only be operated using
the voltage and frequency shown on the
rating plate.
● Only operate the fan unit when it is
completely installed.
● Modifications and alterations to the unit are
not permitted and release Maico from any
guarantee obligations and liability.
Intended use
● Air quality controller for controlling the
supply of fresh air, depending on room air
quality and switching point setting
(sensitivity).

Predictable misuses

Under no circumstances should the unit
be used:
● close to flammable materials, liquids or
gasses.
● in areas subject to explosion hazards.
● in safety applications.
6

Installation, Electrical connection

Danger to life from electric
shock
 Switch the mains fuse off.
DANGER
 Position a warning notice to
avoid the unit being
accidentally switched back on.
Danger of short-circuits
NOTICE
through incorrect feeding of
the power cable into the
housing.
 Guide power cable into
housing correctly.
 Lay a permanent power cable to the
installation location.
 Remove housing cover. To do this,
carefully press the locking hook out of the
grating with a screwdriver. Evenly pull off
housing cover.
 Use 2 screws to secure bottom part of
housing to installation location. See figure
for spacing. Suitable mounting material is
to be supplied by the customer.
 Connect unit according to wiring diagram,
see page 11 and 12.
Start-up
Danger to life from electric
shock. Settings undertaken
once powered up.
DANGER
 Never touch the connection
terminals.
 Ensure that the unit is connected correctly.
Check that the technical data has been
adhered to.
 Switch on mains fuse and wait during the
warm-up period (approx. 5 minutes).
Red LED lights up during this time. The
output relay is closed. The unit is then ready.