H OW TO U S E YO U R T R I N I T Y D E V I C E (CO N T I N U E D)
5) Place the Trinity Device in direct contact with the treatment area. Always keep both spheres in
contact with the skin during treatment to keep microcurrent flowing. Using light to medium pressure
begin your treatment. Note: Facial skin sensitivity varies from person to person. It's completely
normal to not feel any sensation at all. If you do experience tingling, avoid hair follicles and add
more Gel Primer to the area you are treating. The Trinity Device will NOT contract the muscles
when used as instructed.
6) The device emits a dual-tone beep every five (5) seconds to indicate when to move to the next
treatment area. The beep will change to two (2) low tones when the battery needs to be charged.
Note: The Trinity Device will automatically shut OFF after 20 minutes of use.
7) After treatment is complete, massage remaining NuFACE gel primer into skin for additional
skincare benefits.
8) Turn OFF the Trinity Device after every treatment. A descending audible beep is emitted notifying
you that your device is turning off. Clean your device and place back in the charging cradle. See the
"Cleaning" section for proper cleaning instructions.
T R E AT M E N T F R E Q U E N C Y
• Use 5 minutes a day.
• For the first 60 days, use 5 days per week.
• After 60 days, use 2–3 days per week for maintenance.
• Allow 24 hours between treatments.
R E S U LTS
Results may vary based on skin type and skin condition. Best results are achieved with regular use.
C A R I N G F O R YO U R T R I N I T Y D E V I C E
CLEANING
Use a slightly damp, soft, lint-free cloth with water or rubbing alcohol to clean your device after
every treatment. Do not immerse device in water at any time.
CHARGING
Before first use, charge your Trinity Device for 12 hours.
Keep your Trinity Device on the charging cradle and plugged in when not in use. When placed
correctly, you will hear an ascending beep and the lights will increasingly illuminate to indicate that
your device is charging. A fully-charged device should last for approximately 1-2 weeks of use based
on daily usage of 20-minutes, depending on specific treatment attachment usage.

BATTERY CARE

For ideal battery life, charge your Trinity Device when the low battery indicator begins (low tone
beep). If the battery power is drained completely, a full charge cycle of 12 hours is recommended
before use. Use caution prior to using the device if it has been stored or unused for an extended
period of time. Inspect the device and do not use it if there are any signs of internal battery leaks.
TROUBLESHOOTING
If your Trinity Device is not turning ON, please double-check the following:
• The attachment is completely secured to the Trinity Device and fits snugly. Make sure to firmly
press the release button on the back of the device when changing the treatment attachment.
• The Trinity Device battery is fully charged. If not, charge your device for a full 12 hours.
If your device is still not working, if you need assistance, if you need to report unexpected events,
or if you have any questions; please call NuFACE Client Services at 888-360-9171.
7
NF_Trinity_UserManual_ForPrint042919.indd 10-11
WA R R A N T Y
For Devices Purchased in the US: NuFACE
warrants that the NuFACE
®
free of Manufacture defects in materials and workmanship for (1) year from the date of purchase for
the NuFACE Trinity Device, (2) years for the Trinity Pro Device. Abnormal wear and tear, submersions
and drops are not covered by this warranty. This warranty is void if the product has been subject to
accident, misuse, abuse, improper maintenance or repair, unauthorized modification, or any other use
not found in the printed instructions. Must show receipt as Proof of Purchase.
For more information on your warranty, visit www.MyNuFACE.com/pages/warranty-returns
Procedure for Warranty Repairs or Replacement: If warranty service is necessary you can download
a Warranty Form on our website at: www.MyNuFACE.com/warranty or call Client Services at
888-360-9171 to receive further instructions. Please be sure to return all parts (device, cradle and
charger) and include a completed Warranty Form.
NuFACE – Returns / Repairs
1325 Sycamore Ave, Suite A
Vista, CA 92081
USA
1-888-360-9171
For Devices Purchased Outside of the US, International Returns and International Warranties:
All product returns outside of the United States are per your place of purchase – spa, retailer or
distributor. Please consult your receipt or place of purchase for their return and warranty policy.
2AGNA
Conforms to EN IEC/UL: 60601-1, 60601-1-6, 60601-1-11, 60601-2-10, 60601-1-2, 60601-1-4, 60335-1, 60335-2
SY M B O L S
One or more of the following markings may appear on the Trinity Device, User Manual or packaging.
European Conformity
European Representative
REF
Part Number
Refer to Instruction Manual
Manufacturer
Type BF applied part, which is equipment that provides a particular degree of protection
against electric shock. Particularly regarding allowable leakage current and of the
protective earth connection.
devices and attachments are
®
Comply with European Restriction of
Hazardous Substances Directive 2002/95/EC
Product must be disposed of in accordance
with the WEEE directive
FCC-approved equipment authorization mark
Class II double insulated electrical device
4/29/19 3:19 PM
8