WA R N I N G S (CO N T I N U E D)
• Do not operate Trinity Device in the presence of electronic monitoring equipment (e.g., heart
monitors, heart tracing or in close proximity (e.g. 1 m) to shortwave, microwave or electromagnetic
therapy equipment as it may cause the medical equipment to malfunction. Such equipment may
produce instability in Trinity Device output and cause burns at the stimulation site.
• Do not apply stimulation while bathing or showering.
• Do not use this device when there is a tendency to bleed following acute injury or breaks in bones.
• Do not apply stimulation over areas of skin that lack normal sensation.
• Device should not be used at extreme temperatures.
• Keep this device out of the reach of children and pets.
• Discontinue using the device immediately if you suspect the device to be malfunctioning, or not
operating properly. Return the device to NuFACE for examination.
• Do not disassemble the device and attachment as this may cause damage, malfunction, electrical
shock, fire or injury. There are no user-serviceable parts inside.
Note: Disassembly voids the warranty.
P R E C AU T I O N S
The NuFACE Trinity Device is designed for cosmetic use only and for individuals in good health.
If this is not the case for you, please consult your healthcare provider before use.
• The long-term effects of transcutaneous electrical stimulators are unknown.
• If you have suspected or diagnosed heart disease, you should follow precautions recommended by
your healthcare provider.
• Some users may experience skin irritation or hypersensitivity due to the electrical stimulation or
conductive Gel. Irritation can usually be reduced by using an alternate NuFACE conductive medium.
• Skin irritation and burns beneath the electrodes have been reported with the use of other powered
muscle stimulators. If you experience skin irritation or burning, discontinue use immediately.
• If using the Trinity Device causes persistent pain or discomfort, discontinue use immediately.
• A slight tingling sensation may occur while using the Trinity Device. Lowering the intensity may
reduce or eliminate this sensation.
• There may be a perception of flashing lights during the use of your Trinity Device, resulting from
the stimulation of the eye area. If you notice this condition constantly without the use of your device,
consult your healthcare provider.
• Some users may experience a metallic taste in their mouth during the use of your device, resulting
from stimulation and varying sensitivity around the mouth. If you notice this condition constantly
without the use of your device, consult your healthcare provider.
• The battery of the device is not removable by the user. If the device is to be disposed of, do not
put into a fire. Dispose of the device per local regulations.
• Inspect the device and do not use the device if you see any signs of internal battery leaks.
• The Trinity Device is intended to be stored and used at room temperature. Do not store Trinity
Device in the sun or on a hot surface. High temperatures may be damaging. The device should be
operated, transported and stored in the manner specified in this manual. Failure to use and maintain
the device in accordance with the instructions outlined in this manual will void the warranty.
• Only use the power adapter provided with the Trinity Device.
The NuFACE Trinity Device is intended for cosmetic use on the face and neck as described. Any
consequence resulting from misuse, application to other parts of the body or face, connection to
improper voltage sources, dirty spheres, expired or non-NuFACE conductive alternative, or any other
improper application is neither the responsibility of NuFACE nor its affiliates.
G E T T I N G STA R T E D
FOLLOW THESE IMPORTANT STEPS BEFORE USING YOUR NEW DEVICE.
1) Remove your Trinity Device, charging cradle, and external power adapter from the box.
2) Connect the external power adapter to the charging cradle and plug the adapter into an outlet,
keeping it away from any source of water.
3) Place your Trinity Device on the charging cradle. When placed correctly, you will hear ascending
beeps, and the lights will increasingly illuminate to indicate that your device is charging.
We recommend keeping your device on the cradle when not in use.
4) Important: Charge your Trinity Device for 12 hours before first use. All the lights will stay
illuminated when device is fully charged.
5
NF_Trinity_UserManual_ForPrint042919.indd 9
G E T T I N G STA R T E D (CO N T I N U E D)
5) Note: Always firmly press the attachment release button when changing the treatment
attachment. Refer to the Getting to Know Your Device section. Guide the attachment in place and
then release the button to secure the attachment to your Trinity Device. The device will not turn on
if the attachment is not securely in place.
6) Important: Test your skin to make sure you are not sensitive to the NuFACE Gel Primer.
To do so, rub a dime-sized amount of the primer on your forearm and leave for 15–30 minutes before
washing it off. If an allergic reaction (rash, redness, etc) develops, immediately contact NuFACE for
recommendations on alternative NuFACE formulas. You should not initiate treatment with the Trinity
Device until your reaction to the primer has been resolved.
7) Remember to take a before photo of your cleansed face in a well-lit room. After your first
treatment, take an after photo and repeat the process in the same well-lit room every 4 weeks to
track your results.
D E V I C E S O U N D
I N D I C AT E S
Ascending Beeps
Powered ON
Descending Beeps
Powered OFF
Single Beep
Intensity Adjusted
Dual-Tone Beep
End of Glide Interval
Low Tone Beep
Battery Needs To Be Charged
H Y D R AT I N G L E AV E - O N G E L P R I M E R
The essential first step to your microcurrent treatment to ensure optimal results.
Important: Always apply Gel Primer when using the Trinity Device.
Refer to packaging for use by date.
T R E AT M E N T A R E A S
The Trinity Device with Facial Trainer Attachment is designed to stimulate large surface areas of
the face and neck, such as the jawline, cheekbones, and forehead. Avoid applying the device to the
midline of the neck. Follow instructions below for best results, and refer to your Quick Start for more
detailed images.
T R E AT M E N T T E C H N I Q U E
Using light to medium pressure, lift one side of the face and neck at a time using a gliding motion.
Important: Always ensure that both spheres are in contact with the skin during treatment. Refer to
your Quick Start for basic glides treatment for the neck, cheeks, and forehead. For more advanced
treatment options and holds visit our website at MyNuFACE.com
H OW TO U S E YO U R T R I N I T Y D E V I C E
GET READY TO TONE, LIFT, AND CONTOUR.
The instructions below are designed to provide the most effective results when followed correctly.
1) Cleanse your face and neck with an oil-free cleanser. Men should shave before treatment—facial
hair can interfere with the conductivity of the spheres. Note: Any cream, lotion, self tanner, and/or
oil-based products on the skin can block the microcurrent.
2) Apply a mask-like layer of the NuFACE Gel Primer section by section as you treat.
Note: Always apply a NuFACE gel primer when using your Trinity Device.
Reapply if skin becomes dry during treatment to avoid any uncomfortable sensations.
3) Remove your device from the charging cradle and turn it ON by pressing the ON/OFF button.
An ascending audible beep is emitted and the lights will turn on indicating that your device is ON.
4) Adjust the intensity level to your comfort by pressing the intensity control buttons on the front
of your device, either up (+) or down (–). As you increase or decrease intensity, the number of
illuminated lights will change. Note: At maximum intensity, all five lights will be illuminated.
At minimum intensity, only one light will be illuminated.