Error codes display
Error code shown on the
display (B and D)
"E1" or E2" is displayed
"E3" or E4" is displayed
"E7" or E8" is displayed
"HH" is displayed with
beep sound
EN
"LL" is flashing with beep
sound and the compres-
sor is stopped operation.
10
Indication
Upper zone temperature
sensor failure
Defrost sensor failure
Lower zone temperature
sensor failure
High temperature alarm
(the temperature in the wine
cabinet over 78.8°F/26°C)
Low temperature alarm
(temperature in the wine
cabinet below 32°F/0°C)
Possible causes
1. The connection of upper
zone temperature sensor
is loose.
2. Upper zone temperature
sensor is defective.
1. The connection of defrost
sensor is loose.
2. Defrost sensor is defective. Contact the supplier
1. The connection of lower
zone temperature sensor
is loose.
2. Lower zone temperature
sensor is broken.
1. Gas leakage.
2. The capillary copper tube
on the strainer beside the
compressor is blocked.
3. The evaporator fan is de-
fective.
1. The fan of heater is
stopped.
2. The control panel is abnor-
mal.
3. The heater is defective.
Possible solutions
Reconnect the sensor
Contact the supplier
Reconnect the sensor
Reconnect the sensor
Contact the supplier
Contact the supplier
1. Disconnect the power
and connect it again
after 5 mins.
2. Contact the supplier