SILENTUB-100 Axial Extractor Fans
The SILENTUB-100 extractor fan range is
manufactured to the high standards of
duction and quality as laid down by the inter-
national Quality Standard ISO 9001. All com-
ponents have been checked and every one
of the final products will have been
dually tested at the end of the manufacturing
process.
On receipt of the product we recommend
that you to check the following:
1- That it is the correct size.
2- That it is the correct model.
3- That the details on the rating label are
those you require: voltage, frequency...
The installation must be carried out in accor-
dance with the electrical standards in force in
your country.
Installation
IMPORTANT: Before installing and wiring the
unit, ensure that the main supply is discon-
nected.
Fig. 1:
1 : Connection terminals
2 : Outlet with backdraught shutter
3 : Cable entries
The SILENTUB-100 is suitable for wall or
ceiling mounting and can either discharge
directly to the outside or via an individual
ducting system.
Make a hole in the wall or ceiling of 105 mm
dia.
If the unit is to be installed with individual
ducting, use a standard 100 mm dia. duct.
Ensure that there are no obstructions to the
airflow and that the impeller turns freely.
Fix the extractor in such a way that it is not
distorted in order to avoid noise generation
or problems with the rotation of the impeller.
Make sure that the backdraught shutter
opens freely and has not being damaged in
transit. Introduce the mains cable through
one of the cable entry.
Connect the electrical wiring as set out
below.
Electrical connection
The SILENTUB-100 is an extractor designed
for a single phase supply, with voltage and
pro-
frequency as indicated on the rating plate of
the unit. The units are manufactured with
double electrical insulation (Class II) and the-
refore they do not need an earth connection.
indivi-
The electrical installation must include a dou-
ble pole switch with a contact clearance of at
least 3 mm.
The electrical cable must enter the SILEN-
TUB-100 through one of the cable entry.
Once the cable has been introduced proceeds
using the electrical wiring diagram:
Fig.2: Switching the extractor through the
light switch.
Fig.3: To switch the fan through an indepen-
dent switch.
Maintenance
The extractor fan only requires periodical
cleaning using a cloth lightly impregnated
with a soft detergent.
After Sales Service
We recommend you not to try to dismantle or
remove any other parts than those mentio-
ned as any tampering would automatically
cancel the S&P guarantee. If you detect any
fault, contact your S&P dealer.