Maintenance
Check the filter system regularly for leaks and the tubes regularly for
kinks. Bent tubes must be replaced.
The complete filter system should be replaced after 10 years, the
backflow inhibitor every 5 years.
Clean the filter system regularly from the outside with a soft, damp
cloth. Do not use corrosive chemicals, cleaning solutions or harsh
detergents.
Troubleshooting
No flow of water
Cause .................................................... Water supply shut off
Solution ................................................ Open water supply to the upstream
shut-off valve ..................................... Check and close the locking handle
Cause .................................................... Backflow inhibitor has been
Solution ................................................ Mount the backflow inhibitor on the
No or limited flow of water despite opened water supply
Cause .................................................... Pipe pressure too low
Solution ................................................ Check pipe pressure. If the error
Cause .................................................... Filter head not mounted in the
Solution ................................................ Remove the filter head and mount
Leak
Cause .................................................... Screw connections not properly
Solution ................................................ Check pipe pressure. Check all
on the filter head.
mounted on the output side.
input side.
persists, check the filter system
and filter cartridge, and replace if
necessary.
direction of flow.
in the direction of flow.
fitted.
screw connections and check that
seals are present.
Replace the filter system if the
error still occurs.
Handling
EN
21