12. The control of the optical detection of the obstacle accord-
ing to the EN 12445 standard (type D device) is performed
with the 700x300x200mm test parallelepiped with 3 black
faces and 3 polished white or mirrored faces as indicated in
figure 14 and according to chapter 7 of the EN 12445:2000
standard (or enclosure A of prEN12445:2005).
13. If a pressure sensitive device PSPE (sensitive edge) is
connected to the system, the following tests must be
performed to verify that it is functioning correctly:
Start a down manoeuvre and press the pressure sensitive
device (as in figure 15) checking that the automation per-
forms a short inversion and then stops. Repeat the test
by starting an up manoeuvre.
14. The control of the PSPE pressure sensitive device of the
F210S according to the EN 12445 standard is performed
by measuring the force at the points foreseen in chapter
5 of the EN 12445 standard, if the hazardous situations,
which have been caused by the movement of the leaf,
have been safeguarded through the limitation of the
impact force (type C).
5) Additional information
This chapter looks at particular actions or programming related to F210S.
5.1) F210S signals and status
The status and functioning of the F210S photocell are indicated by the DL1 and DL2 LEDs.
Recognising the type of signal can be useful to distinguish faults or resolve possible problems.
Table 1
"DL1" LED
(SENSITIVE EDGE)
Off
On
Flashing light (at 50%)
On with short switch-off
(every 2 seconds)
Rapid flash
(DL2 off)
Rapid flash
(alternating with DL2)
"DL2" LED (PHOTOCELL)
On
Slow flash (1S)
Off (only with the DL1 flas-
hing rapidly)
Rapid flash
(alternating with DL1)
Very rapid flash
Meaning
8.2KΩ resistance on the sensitive edge
input measured
Resistive value outside the specification
measured
Resistance at approximately 4.1KΩ on
the sensitive edge input measured
Triggering of sensitive edge with
inversion deactivation
Photocell starting phase
Communication attempt with motor or
control unit
Meaning
Infrared PHOTOCELL signal not received
Infrared PHOTOCELL signal correctly
received
Photocell starting phase
Communication attempt with motor or
control unit
The JP1 jumper does not select any
PHOTOCELL intervention direction
14
15
Action
Sensitive edge Ok
Check the cause of the sensitive edge activation
Triggering of the sensitive edge inversion
deactivation switch S (cap 3.3.1)
Only the up movement is allowed
Wait a few seconds
This phase could even last as long as one minute,
if this signal continues for more than a minute try
turning the motor off and on again
Action
Remove obstacle or align TX and RX
Signal OK
Wait a few seconds
This phase could even last as long as one minute,
if this signal continues for more than a minute try
turning the motor off and on again
Select the PHOTOCELL intervention direction by
means of the JP1 jumper
GB