Temperature sensor
The temperature sensor will calibrate first and after about 15
minutes it will indicate the right temperature. At water
temperatures below 12°C the system will shut down
automatically. The settings are preserved and above 12°C
the device will switch on again. The T-Flow Tronic can be
switched off manually by lowering the rate to 0% (Off ).
Locking the keys
The display unit has a key deactivation function to prevent
inadvertent changes to the settings. Press the middle key for
3 seconds to lock the keys. The message appears hold 3 sec.
to (un)lock. Pressing the middle key for 3 seconds unlocks
the keypad. This function can be turned on or off at any time.
Screen sleep mode
If no input is made to the operating display for 30 seconds, it enters 'sleep mode'
and the screen light is turned off. This maintains the optimal quality and lifetime
of the screen. As soon as a key is touched, the light turns on again. After 3 minutes, the
keypad locks automatically.

STORAGE AND CLEANING

At water temperatures below 12°C the system will shut down automatically. During
winter time, you should remove the T-Flow Tronic from the pond. Store it in a dry
and frost-free place.
In proportion to the amount of use, the size of the anode will decrease. If the anode
needs replacing or becomes dirty, this is indicated on the display with the message
ERROR 1. Continuous use at a high dose, may cause the anode to be replaced after
only a few weeks. With variable use, it can be active from a few months to a year.
When performing maintenance, always unplug the pump first. After removing the
cathode (2), the anode (1) can be unscrewed from the housing and it can be replaced.
Remove the dirt from the anode (1) and cathode (2) using water and the little
brush, after a failure of the pump or ERROR. To be sure of an optimum operation,
the end cap with cast in contact points should be replaced at least once a year.
New anodes (1) and end caps (3) are available at the specialized trade.

SAFETY REGULATIONS

Ensure a durable grounded connection to the electric mains and use an earth
leakage circuit breaker of nominal 30 mA. With damage to the device, control display
or cable the apparatus should no longer be used. With activity in or around the pond,
all elec-trical pond apparatuses should be unplugged. This also applies to
Flow Tronic. The T-Flow is meant for use next to a pond. Any other use is forbidden by
the manufacturer.
the T-