TYP 4133, 4135, 4138, 4139, 4153, 4155, 4158, 4159,
4143, 4145, 4148, 4149, 4163, 4165, 4168, 4169
MONTAGE · ASSEMBLY · MONTAGE · MONTAGE
Attention! Be sure to have the nature of the wall checked by qualified personnel before assembly. Assembly should only be carried out by qualified persons and the assembly
instructions must be strictly adhered to. The sets of mounting brackets are only suitable if the nature of the wall and the pressure resistance levels meet those stated in the table
below. The unit cannot be mounted on light walls. Please note that a different mounting method must be chosen by qualified personnel for other types of wall. hülsta cannot be held
responsible for the correct choice of any other type of mounting. When mounting the unit, please also make sure that there are no electrical installations or other utility lines near the
mounting area. Check this using an appropriate search device. Please note that plastic pipes will not be detected.
Mounting set 1 (Mat. no.1410886 / type 8888)
for 2 wall connection points
1x
TVM-STV-K 280
6x
TVM-IGA 6x93
The set is only suitable for use in connection with the types of walls stated below.
Please note that the pressure resistance levels must under no circumstances fall below
those stated.
Optional mastic gun (Mat. no.1410888 / type 2222)
(Vertically) perforated bricks
Hollow light concrete
blocks
min. 5 mm
Anchoring depth
Depth of drilled hole
SEITE 22
MONTAGEANLEITUNG
TV-Elemente
TV UNITS
ELEMENTS POUR TV
TV-ELEMENTEN
2x
TVM-Z-SM
TVM-Z-SH 16x105
6x
DIN 125 / 6.4
DIN 933 / 6x20
1x
Pressure resistance
>/= 4 N/mm²
Pressure resistance
>/= 2 N/mm²
Mounting set 2 (Mat. no.1410887 / type 5555)
6x
1x
TVM-STV-K 280
6x
9x
TVM-Z-SH 16x105
9x
DIN 933 / 6x20
The set is only suitable for use in connection with the types of walls stated below.
Please note that the pressure resistance levels must under no circumstances fall below
those stated.
Recommended kind of drilling:
Rotary drilling: With a normal power drill, without percussion setting in per-
forated bricks (so that the connecting sections do not break and the hollow
section become too large). Holes must always be thoroughly cleared of any
drilling remains afterwards.
Recommended kind of drilling:
Rotary drilling: With a normal power drill, without percussion (so that the
connecting sections do not break and the hollow section become too large).
Holes must always be thoroughly cleared of any drilling remains afterwards.
Depth of drilled hole
The hole itself must be deeper than the depth of anchoring.
Please also follow the additional enclosed information about
compound mortar from the Tox Company to ensure correct mounting.
for 3 wall connection points
1x
TVM-STV-K 150
9x
DIN 125 / 6.4
TVM-IGA 6x93
4x
TVM-Z-SM
9x

Publicité