Operation
Operating elements
A Device with coin slot
B Device with start button
1 Throwing in the coin
2 Indicator lamp
3 Coin return
4 Start button
5 Mat feeder
6 Mat ejector
Cleaning the mat
Device with coin slot:
Insert a coin in the coin slot.
The device starts.
Device with start button:
Press the start button.
START
The device starts.
Turn the side of the mat to be
cleaned downwards.
Push the mat into the mat feed-
er and hold it.
Insert, withdraw, and turn the
mat in the device several times
until all points of the mat have
been cleaned.
Pull the mat out of the device.
Note:
If the mat is released, it will move through
the device and be ejected at the mat ejec-
tor.
Settings
Setting the run time
Note:
The adjustable run time applies to the in-
sertion of one of the following coins:
– 50 Eurocents
– 50 British pence
– 1 Swiss franc
– 1 Polish złoty
– 5 Norwegian Kroner
Remove the lid (see "Maintenance and
care/Maintenance tasks/Removing the
lid").
8
1 "PRG" button
2 LED 3
3 LED 1
4 "P1" button
5 Control
Press the "PRG" button and hold it
down until LED 3 illuminates.
The "adjustment" operating mode is ac-
tivated.
Note:
The "adjustment" operating mode will end if
no buttons have been pressed for 10 sec-
onds.
The adjustment begins with a run time of 0
seconds.
Maximum run time is 10 minutes. If this set-
ting is reached, LED 1 will flash quickly.
Press the "P1" button briefly.
LED 1 flashes quickly and the run time
is increased by 5 seconds.
Press and hold the "P1" button.
LED 1 flashes slowly and the run time is
increased by 30 seconds.
Set the desired run time by pressing the
"P1" button repeatedly.
To confirm the set run time, press the
"PRG" button until LED 3 flashes quick-
ly:
The run time has now been saved.
Shutting down
Set main switch to "0".
Maintenance and care
DANGER
Risk of injury due to inadvertently starting
up device and also due to electric shock.
Before starting any maintenance and
care work, turn the main switch off "0"
and ensure that it will not be turned on
accidentally.
Daily
For device with coin slot: Empty the
coin cassette (see "Maintenance
tasks").
Empty the dirt receptacle (see "Mainte-
nance tasks").
Check the general condition of the de-
vice.
Have damaged parts replaced.
Weekly
Remove dirt from the mat ejector.
Clean the device.
Every 500 cycles
Lubricate the locks with penetrating oil
(Caramba, WD 40).
2
-
EN
Every 8000 cycles
Replace the brush (see "Maintenance
tasks").
Maintenance Works
Emptying the coin cassette
1 Door
2 Lock
3 Coin cassette
Open door.
Remove and empty the coin cassette.
Removing the front cover
1 Lock
2 Cover
Open locks.
Remove cover.
Emptying the dirt receptacle
Remove the front cover (see above).
1 Dirt receptacle
(not included in delivery)
Remove and empty the dirt receptacle.
Reinsert the dirt receptacle.
Install and lock the cover.