hazard. Make sure the appliance is well ventilated.
• Turn on the lighting switch, check the light is nor-
mal.
• The digital temperature controller is delivered
with default parameters. Do not alter the param-
eters casually except for special need.
• When running for the first time, it should run
without load for 2 hours to ensure the refriger-
ation system is working normally. Only when the
temperature within the appliance is reduced with-
in the indicated scope can the food be put into the
appliance.
• Don't put too much food in the appliance to pre-
vent instantaneous high load. The food shall not
6.2. PACKAGING
Upon receipt of the appliance, check the packaging
for any transport damage.
Carefully remove the external cardboard, loosen the
bolts fixing the appliance to the pallet (if present -
they secure the appliance from movement during
transport), put the appliance aside and remove the
protection film from the outer housing.
6.3. LEVELLING
To ensure correct functioning it is important to level
the appliance. Correct levelling allows for reduction
of vibration generated by the unit in operation.
The appliance is supplied with adjustable feet.
Thoroughly check the levelling with the use of a
spirit level.
CAUTION!
To ensure proper functioning of the cooling/
freezing appliance, strictly follow the instructions
below:
• Do not put the appliance in a place exposed to di-
rect sunlight and near appliances emitting radi-
ation, such as: heat lamps, stoves, radiators etc.
• Avoid integrating or building over of the appliance.
• Do not place any objects on the top of the appli-
ance housing where the refrigerating unit is lo-
cated.
• Do not place the appliance in a room with relative-
ly high humidity (water can liquify on the housing).
block the air outlet and air inlet. Nor shall it be
close to side glass. Otherwise it will lead to con-
densation.
• To keep the taste of the food, please have the
equipment running 24 hours a day.
• During the frosting process, the temperature of
the appliance may rise slightly. When the frosting
end, it will return to normal.
ATTENTION: During transport, avoid skew the unit
from the vertical by an angle greater than 30 °, If
necessary, wait approximately 3-4 hours before
running, until the oil flows to the unit. Otherwise,
the condensing unit may be damaged.
By recycling of packaging materials such as plas-
tics, steel, cardboard and wood, we significantly
contribute to saving raw materials and waste re-
duction.
Comply with local regulations regarding the meth-
od and place of disposal of the appliance packaging
materials.
• Do not place the appliance in narrow recesses (if
there is no air circulation, the appliance will not
function properly).
• Do not cover ventilation openings located on the
housing.
• Do not place the appliances back to back (they will
not operate properly).
Ensure that the room where the appliance is placed
is properly ventilated, also outside of working
hours; it is crucial for proper operation of the re-
frigerating unit.
EN
7