ADJUSTING BURNER PRIMARY AIR (291BR1G - 291BR2G - 291BR3G)
To carry out this operation,
proceed as follows.
1 - Turn off the gas supply
tap.
2 - Remove the knob (B).
3 - Undo the screws (C)
and remove the control
panel (D).
4 - Undo
the
screw (E).
5 - Set the bush (F) at the
distance as shown in
the figure.
6 - Tighten the screw (E).
After making the setting, seal the screw with
paint.
7 - Replace the control panel (D) and the knob (B)
on completion of the operation.