Alignment Report Print Out - SKF Maintenance Products TMEA 1P/2.5 Mode D'emploi

Procédure d'étalonnage
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
The chapter 4.2 applies to TMEA 1PEx and TMEA 1P/2.5 with the
optional printer TMEA P1.
4.2

Alignment report print out

The print out contains the following data fields:
a) Name of the equipment
b) Maximum rotational speed
c) Name of the operator
d) Date and time of the saved measurement data
e) Selected dimension unit: metric or imperial
f) Machines configuration
g) Vertical alignment
h) Vertical alignment
i) Vertical alignment
j) Vertical alignment
k) Vertical alignment
l) Horizontal alignment
m) Horizontal alignment
n) Horizontal alignment
o) Horizontal alignment
p) Horizontal alignment
q) Notes
34
distances A, B and C (mm or in)
resulting angular error
(mm / 100 mm or mil / in)
resulting parallel offset (mm or mil)
resulting height position of the front
feet
resulting height position of the rear
feet
resulting angular error
(mm / 100 mm or mil / in)
resulting parallel offset (mm or mil)
resulting sideways position of the
front feet
resulting sideways position of the
rear feet
Shaft Alignment Tools
TMEA 1P/2.5 / TMEA 1PEx

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tmea 1pex

Table des Matières