Feet On The Ground; Attachment Of Measuring Units - SKF Maintenance Products TMEA 1P/2.5 Mode D'emploi

Procédure d'étalonnage
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
3.2

Feet on the ground

If there is any doubt whether the machine is resting equally on all feet
please check for so called "soft foot". The procedure for this operation
is described in chapter 5.1.
3.3

Attachment of measuring units

a) Use the chain fixtures to attach the measuring units firmly to the
shafts. Make sure that the M-marked unit is attached to the
Movable machine and the S-marked unit to the Stationary machine.
For diameters larger than 150 mm an extension chain (TMEA C2) is
required.
Fig. 8.
Attachment of mechanical fixture
If it is not possible to attach the fixtures directly to the shafts (e.g. in
case of space problems) the fixtures can be attached to the coupling.
Note!
It is highly recommended to position the measuring units at equal
distance from the middle of the coupling.
18
Shaft Alignment Tools
TMEA 1P/2.5 / TMEA 1PEx

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tmea 1pex

Table des Matières