Fulgor Milano F4PGK305S1 Instructions D'installation page 15

Masquer les pouces Voir aussi pour F4PGK305S1:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FOR ALTERNATIVE PIPING METHODS TO CONNECT THE
APPLIANCE TO THE GAS SUPPLY, A TRAINED SERVICE MAN
OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLY
CONNECTION.
Leak testing of the appliance shall be conducted by the Installer
according to the Instructions given.
Unless prohibited by local codes or ordinances, a new A.G.A.
- Certified, flexible metal appliance connector may be used to
connect this appliance to its gas supply.
The connector must have an internal diameter not less than
nominal 1/2" NPT pipe and be no more than 5 feet in length.
A 1/2" NPT x 1/2" flare union adapter is required at each
end of the flexible connector.
If a flexible connector is used assure that both the appliance
pressure regulator and manual shut-off valve are joined
solidly to other permanent hard piping (either gas supply or
the appliance manifold) so as to be physically stationary. See
figure.
GASKET
FLARE UNION ADAPTOR
APPLIANCE PRESSURE
REGULATOR, SUPPLIED
(OBSERVE DIRECTIONALITY
OF GAS FLOW)
FLARE UNION ADAPTOR
FLEXIBLE APPLIANCE
CONNECTOR
(5 FT.) MAX
(1.52 m) MAX
FLARE UNION ADAPTOR
GAS SHUT-OFF VALVE
1/2" NPT PIPE
(STATIONARY SUPPLY PIPE)
GASKET
NO APPLIANCE
MOUNTED BELOW
THIS COOKTOP
CAUTION
Do not attempt to attach the flexible connector directly to an
external pipe thread.
Connection requires flare union adapters.
For Massachusetts Installations:
1. Shut-off valve must be a "T" handle gas cock.
2. Flexible gas connector must not be longer than 36 inch.
3. Not approved for installation in a bedroom or a bathroom
unless unit is direct vent.
MANIFOLD
ENTRANCE
1/2" NPT PIPE
NIPPLE ELBOW
WALL OVEN MOUNTED
IN CABINETRY BELOW
THIS COOKTOP
FLARE UNION ADAPTOR
FLEXIBLE APPLIANCE
CONNECTOR (5 FT. ) MAX
FLARE UNION ADAPTOR
APPLIANCE PRESSURE
REGULATOR, SUPPLIED
(OBSERVE DIRECTIONALITY
OF GAS FLOW)
1/2" NPT PIPE NIPPLE
GAS SHUT-OFF VALVE
1/2" NPT PIPE
(STATIONARY SUPPLY PIPE)
EN
11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F6pgk305s1F4pgk365s1F6pgk365s1

Table des Matières