MCS Master BCM 191AB Manuel D'utilisation Et De Maintenance page 19

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 42
►1.13. Make sure the polarities are
respected when connecting to the
mains. We recommend using a suita-
ble residual current device (see name-
plate).
►1.14. The cooler can withstand a max-
imum water inlet pressure of 3 Bar.
If the pressure of the water supply is
higher, a pressure reducer must be in-
stalled.
►1.15. Only fill the cooler tank only with
clean water.
►1.16. We recommend using horizontal
coverage to protect from weathering,
in order to preserve the cooler over
time.
►1.17. It is forbidden to alter, tamper
with or adjust the cooler and the elec-
tricity or water supply after installa-
tion, if it is not carried out by qualified
personnel.
►1.18. Do not obstruct, even partially,
the air vents of the cooler, in order to
prevent a hazard.
►1.19. In order to prevent serious dam-
age, do not let dust, dirt or other mate-
rials come into contact with the cool-
er.
►1.20. We recommend using the cooler
with ambient temperatures between
18°C and 45°C and with water temper-
ature below 45°C.
►1.21. In order to prevent serious
breakdowns, when the temperatures
drop to about <2°C, completely empty
the tank and the pipes that supply wa-
ter to the cooler.
►1.22. Disconnect the power supply
when you handle or service the cooler
(use personal protective equipment in
order to prevent any hazards).
►1.23. If the power supply cable is dam-
aged, it must be replaced by a techni-
cal support centre to prevent any risk.
►1.24. Protect the power cable from po-
tential damage caused by the move-
ment of vehicles, pedestrians, weath-
ering and heat sources.
►1.25. If the cooler malfunctions, con-
tact the technical support centre.
►1.26. Unplug the cooler from the pow-
er supply, when it is not used for a
medium to long term period.
►1.27. The water used to fill the cooler
tank must come from an aqueduct. If
it is not possible to draw from an aq-
ueduct, the water introduced must be
subjected to a sanitation treatment,
according
to
98/83/EC.
-We recommend using water with a
hardness of less than 15°f.
-The cooler tank must be emptied and
sanitised periodically depending on
the use.
-The cooling pad surfaces must be
periodically inspected and sanitised
depending on the use.
-For sanitation operations, biocidal
products that comply with European
regulation no. 582/2012 must be used.
►►►2. UNPACKING
IMPORTANT: IT IS STRICTLY FORBID-
DEN TO STACK TWO OR MORE COOL-
ERS.
►2.1. Remove all packaging material
used to pack and deliver the cooler and
dispose of it in compliance with current
standards.
►2.2. Remove all items from the packag-
ing.
►2.3. Check for any damage incurred dur-
ing transport. If the cooler appears dam-
aged, immediately inform the dealer from
whom it was purchased.
►►►3. ASSEMBLY AND INSTAL-
LATION (ONLY FOR QUALIFIED
PERSONNEL)
NOTE: TO ACCESS THE INTERNAL
PARTS OF THE COOLER, REMOVE THE
SCREWS AND EVAPORATION PANELS,
European
Directive
en
it
de
es
fr
nl
pt
da
fi
no
sv
pl
ru
cs
hu
sl
tr
hr
lt
lv
et
ro
sk
bg
uk
bs
el
zh

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bcm 191alBcm 191auBcm 311abBcm 311auBcm 511abBcm 511au

Table des Matières