Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
4
Pairing an outside temperature sensor
The pairing must be done in the boiler room on first
initialisation.
1
5

Cancel pairing

To cancel the pairing on all circuits and outside temperature sensors,
press the button on the radio module for 10 seconds (until the light
goes off and then flashes).
6
Troubleshooting
Status of the light on the boiler's radio module
Light on during the boiler start-up phase
The light flashes slowly during the boiler start-
up phase
The warning light flashes rapidly
Warning light on after the pairing button has
been pressed
The warning light is pulsing
10
Each outside temperature sensor is given a unique identifying
number in the factory, which enables the radio module to recognise
it. This identifying number is transmitted to the radio module by the
pairing sequence described below.
2
- Switch the boiler off and switch back on.
- If the problem persists, contact the fitter. The radio module is damaged.
- No remote control or outside temperature sensor has been paired with the radio module.
- If the rapid flashing does not stop 10 seconds after being switched on, a radio remote
control is paired with a circuit that already has a wire remote control. Re-pair the radio
remote control with another circuit or connect the wire remote control to another circuit.
- The boiler's radio module is in pairing mode with a radio remote control or an outside
temperature sensor. This mode remains activated for a maximum of 2 minutes.
- The radio module has communicated with the radio remote control or an outside
temperature sensor.
AD252
Press the button on the radio module using the tip of a ballpoint
pen. The light on the radio module comes on.
Press the button on the outside temperature sensor. The light
on the outside temperature sensor comes on. The light goes
off briefly every 3 seconds when the radio module picks up the
signal from the sensor transmitting information on the outside
temperature.
After a few seconds, the light on the radio module goes off. The
light comes on briefly every 3 seconds to confirm reception of
the outside temperature. To exit the pairing mode, press the
button on the outside temperature sensor.
The radio module exits the pairing programme after 2
minutes. The outside temperature sensor automatically
exits the pairing mode after 5 minutes.
Meaning / Solution
24/06/2011 - 300020522-001-F

Publicité

Table des Matières
loading

Table des Matières