Problem
The nails are driven in too deep.
The nails are not driven in deep enough. The rated pressure of the compressed-air supply is
The pneumatic tool skips nails or has a
too large cycle feed.
Frequent jamming of nails in the shot
duct.
The driven nails are bent.
Contrary to working with normal operat-
ing speed, the nails are not driven in
deep enough at higher operating speed.

Accessories

For more information on the complete quality accessories program,
please refer to the Internet under www.bosch-pt.com or contact your
specialist shop.
After-sales Service and Customer Assistance
Our after-sales service responds to your questions concerning mainte-
nance and repair of your product as well as spare parts. Exploded views
and information on spare parts can also be found under:
www.bosch-pt.com
Our customer service representatives can answer your questions con-
cerning possible applications and adjustment of products and accesso-
ries.
Bosch Power Tools
Cause
The rated pressure of the compressed-air supply is
too high.
The depth stop is set too deep.
The buffer is worn.
too low.
The depth stop is set too high.
The length and diameter of supply-air hose 15 do not
correspond with the data of this pneumatic tool.
The supply-air hose 15 is bent/creased.
The fasteners being used are not permitted.
The magazine 10 is not operating correctly.
The spring of the magazine slider is too week or de-
fective.
The sealing ring of the piston is worn or damaged.
The fasteners being used are not permitted.
The driver blade is damaged.
The interior diameter of the supply-air hose is too
low.
The compressor is not suitable for fast operating
speeds.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham
Uxbridge
UB 9 5HJ
Tel. Service: +44 (0844) 736 0109
Fax: +44 (0844) 736 0146
E-Mail: boschservicecentre@bosch.com
English | 21
Corrective Measure
– Reduce the compressed-air supply. 4 bar may not
be fallen below.
– Adjust the depth stop to the desired depth.
(See "Adjusting the Depth Stop", page 18)
– Contact an authorised service agent for Bosch
power tools.
Have the component replaced there.
– Increase the compressed-air supply. 8 bar may
not be exceeded.
– Adjust the depth stop to the desired depth.
(See "Adjusting the Depth Stop", page 18)
– Use a supply-air hose with the correct dimensions.
(See "Technical Data", page 16)
– Correct the bend/crease in the supply-air hose.
– Use only original accessories.
Only the fasteners (nails, staples, etc.) specified
in table "Technical Data" may be used.
– Clean and lubricate the magazine slider 11 as re-
quired and make sure that the magazine 10 is not
dirty/soiled.
– Contact an authorised service agent for Bosch
power tools.
Have the component replaced there.
– Contact an authorised service agent for Bosch
power tools.
Have the component replaced there.
– Use only original accessories.
Only the fasteners (nails, staples, etc.) specified
in table "Technical Data" may be used.
– Contact an authorised service agent for Bosch
power tools.
– Contact an authorised service agent for Bosch
power tools.
Have the component replaced there.
– Use a supply-air hose with the correct dimensions.
(See "Technical Data", page 16)
– Use a compressor that is sufficiently dimensioned
for the number of connected pneumatic tools and
the operating speed.