Intended Use
This appliance is intended for domestic use
or for household-based, non-commercial
applications. Household-based applications
include, e.g. usage in employees catering
facilities for shops, offices, agricultural and
other commercial operations, as well as
usage by guests of guest houses, small hotels
and similar residential establishments.
Safety information
Please read this installation instruction
manual carefully, then act accor dingly!
Store for future reference. These installa-
tion instructions must be included when
transferring this appliance to a new owner.
The appliance may only be connected
and put into operation by a qualified
professional.
Install and operate the appliance as de-
scribed in the text and illustrations. We do
not accept liability for damage resulting
from failure to heed these instructions.
The supplied water connection nozzles
must be used and installed as shown in
the supplementary sheets. Make sure that
a check valve is installed in the cold water
supply line.
This appliance is intended for use up to an
altitude of 2000 m above sea level.
The appliance may only be installed and
stored in a frost-free room (due to residual
water).
Risk of electric shock!
Switch off the mains voltage supply
immediately if a fault occurs.
Disconnect the power supply before
opening the appliance.
Immediately shut off the cold water
supply to the appliance should it leak.
The statutory regulations of the respective
country, as well as those of the local electric-
ity and water suppliers, must be adhered to.
The continuous-flow heater is a Class I
appliance and must be connected to the
protective earth.
6
EN
Caution: Earthed water pipes may give the
appearance of a connected protective earth.
The appliance must be permanently
connected to installed pipes. The conduc-
tor cross-section must comply with the
installed appliance power.
To guarantee compliance to relevant safety
regulations, an all-pole separator must
be fitted during installation. The contact
opening must be at least 3 mm.
The continuous-flow heater is only suitable
for closed (pressurised) operation.
The tap and outlet fittings must be ap-
proved for operation with closed (pressur-
ised) continuous-flow heater systems.
The continuous-flow heater can be oper-
ated with cold or pre-warmed water (only
applies to DES). Observe the technical
data and the special accessories for this
purpose.
The water's specific electrical resistivity
must not be less than 1 300 Ωcm. Ask the
local water utility company regarding the
electrical resistivity of the water.
The continuous-flow heater is suitable for
connection to DVGW-tested plastic pipes.
Disconnect the electrical connection
cable from the supply and shut off the
water supply before connecting the
appliance!
Connect the water supply and then
connect the electrical supply.
Only make the openings which are re-
quired for installation on the rear of the
appliance. If the appliance is reinstalled,
the unused openings must be provided
with watertight sealing.
Do not touch electrically live parts after
installation.
Do not use aggressive or abrasive cleaning
detergents!
Do not use a steam cleaner.