man_ECO1700('20) V7.indd 119
man_ECO1700('20) V7.indd 119
Ash on the
Flue pipes are not air-
floor around
tight
the stove
Broken, worn or dam-
aged door seal
Stove in con-
The room temperature
stant mode,
desired by the user has
the display
been reached
shows: "Eco"
Display shows
No error. The stove
"SERV"
requires a service every
1200 hours of operation.
The stove will simply
continue to work.
Display shows
An attempt is being
"Atte"
made to start the stove
while it is still in the
cooling-down phase.
Stove goes
Pressure sensor/switch is
out. The alert
defective
shown is "AlAr
The exhaust/flue/chimney
/ dEp / Sic /
is blocked
Fail" and the
LED 5 will be
Electronic printed circuit
shown on the
board is defective.
display.
Excessive flue length
Unfavourable weather
conditions
Stove is overheating
The room air recircula-
tion blower is defective
Temporary power outage
Safety thermostat is
defective
Only to be done by an approved flue fit-
ter: Flues that are not airtight can harm
your health. Seal the pipe fitting immedi-
ately (use Loctite 598 or equivalent prod-
uct) and/or replace the pipes.
Replace the seal. Only to be done by a
Qlima-approved technician
This is not an error. The stove is working in
eco mode. This mode can be changed with
the remote control
The stove requires a service. Contact a
Qlima-approved service technician. The
technician will carry out a service on the
stove and reset the notification.
Wait until the cooling down phase has
been completed before trying to reignite
the stove.
Replace the pressure switch. Only to be
done by a Qlima-approved technician
Have the exhaust/flue/chimney cleaned im-
mediately by an approved chimney sweep.
Contact an approved chimney sweep.
Replace the electronic printed circuit
board. Only to be done by a Qlima-ap-
proved technician
Consult a flue specialist to check whether
the flue complies with the law. Consult
a Qlima-approved technician to check
whether the flue is suitable for the stove.
Strong winds can cause negative pressure
in the flue. Check and restart the stove.
Room temperature too low. Open doors
to other rooms. If the problem persists,
contact a Qlima-approved technician.
The safety thermostat on the stove has
been triggered. Let the stove cool down,
then reset the safety thermostat by remov-
ing the protective cap (figure 16) and
pressing the reset button (figure 17).
Replace the blower. Only to be done by a
Qlima-approved technician
A power cut when the stove is in opera-
tion can cause the interior to overheat. Al-
low the heater to cool down and restart it.
Replace the safety thermostat. Only to be
done by a Qlima-approved technician
4
119
30-07-20 16:47
30-07-20 16:47