4
112
man_ECO1700('20) V7.indd 112
man_ECO1700('20) V7.indd 112
- soot on glass
- more ash and unburnt granules
- higher maintenance costs
Even when good, standardised pellets are used, it is not unusual for
G
there to be differences in the combustion speed, ash production and
build-up of debris. If a different type of pellet is used to the ones used
during commissioning, the stove must be set up again by a Qlima-
approved service technician.
G
Store and transport the pellets in absolutely dry conditions. Wooden
pellets can expand considerably when they come into contact with
water.
Contact the Qlima sales person or approved Qlima fitter for more information
about pellets.
5.2 FILLING THE PELLET HOPPER
Open the cover of the pellet hopper on top of the stove and carefully empty the
pellets into it to until 3/4 full. Make sure that no pellets fall into the stove. Close
the cover again.
Never touch any rotating parts in the pellet hopper. To avoid the risk
of coming into contact with rotating parts in the pellet hopper, it is
recommended that you always completely switch off the stove by
removing the plug from the power socket.
If the hopper needs refilling during operation, make sure the pellets and/
or pellet bag cannot come into contact with the hot parts of the stove
as this could lead to dangerous situations. Make sure never to touch any
rotating parts in the pellet hopper.
6. MAINTENANCE
The heat, ash and residue resulting from burning the fuel means regular clean-
ing and servicing by both the end user and an authorised technician are required.
Thorough and regular cleaning of the stove is important for safety and the ef-
ficient operation of the appliance as well as increasing its lifespan. Do not use
steel wool, hydrogen chloride or other corrosive, aggressive or abrasive products to
clean either the interior or exterior of the stove. Especially after extended periods
of non-use the stove and the flue system must be checked for blockages.
6.1 MAINTENANCE TO BE PERFORMED BY THE END USER
11.
Do not bend or pinch the power cord.
Only carry out maintenance on the stove after checking that it has
completely cooled off both inside and out!