TEChNICAL SuppOrT

For technical support and repair assistance in the U.S., call
the DENTSPLY Professional Cavitron Care
Service at 1-800-989-8826, Monday through Friday, 8:00
A.M. to 5:00 P.M. (Eastern Time). For other areas, contact
your local DENTSPLY
Professional representative.
®
SuppLIES &
rEpLACEmENT pArTS
To order supplies or replacement parts in the U.S., contact
your local DENTSPLY Professional Distributor or call
1-800-989-8826, Monday through Friday, 8:00 A.M. to 5:00
P.M. (Eastern Time). For other areas, contact your
local DENTSPLY Professional Representative.
SECTION 1:

Indications For use

Ultrasonic Procedures
• All general supra and subgingival scaling applications
• Periodontal debridement for all types of periodontal
diseases
• Endodontic procedures
Air Polishing Procedures
• Removal of a variety of extrinsic stains, e.g. tobacco,
coffee, tea, chlorhexidine.
• Prophylaxis of orthodontic patients.
• Preparing tooth surfaces prior to bonding and sealant
procedures.
SECTION 2:

Contraindications

• Ultrasonic Systems should not be used for restorative
dental procedures involving the condensation of
amalgam.
• Cavitron
PROPHY-JET Prophy Powder is a water-soluble
®
Sodium Bicarbonate powder. Therefore, this powder is
not recommended for patients on a sodium restricted
diet. Cavitron
JET-Fresh Prophy Powder is a sodium
®
free powder and can be used on patients who are on
sodium restricted diets.
SECTION 3: warnings
• Persons fitted with cardiac pacemakers, defibrillators
Factory Certified
SM
• There are a variety of pacemakers and other medically
• It is the responsibility of the Dental Healthcare
• The use of High Volume Saliva Evacuation to reduce
• Do not direct the air polishing stream at soft tissue or
• Where asepsis is required or deemed appropriate in
• During boil-water advisories, this product should not
• Prior to beginning treatment, patients should rinse with
4
and other active implanted medical devices, have been
cautioned that some types of electronic equipment
might interfere with the operation of the device.
Although no instance of interference has ever been
reported to DENTSPLY, we recommend that the
handpiece and cables be kept 6 to 9 inches (15 to 23
cm) away from any device and their leads during use.
implanted devices on the market. Clinicians should
contact the device manufacturer or the patient's
physician for specific recommendations. This unit
complies with IEC 60601 Medical Device Standards .
Professional to determine the appropriate uses of this
product and to understand:
– the health of each patient,
– the dental procedures being undertaken,
– and applicable industry and governmental agency
recommendations for infection control in dental
healthcare settings,
– requirements, and regulations for safe practice of
dentistry; and
– these Directions for Use in their entirety, including
Section 4 Precautions, Section 6 Infection Control, and
Section 10 System Care.
the quantity of aerosols released during treatment is
highly recommended.
into the sulcus. Tissue emphysema has been reportedly
caused when the air/water/powder stream was directed
at the soft tissue or into the sulcus.
the best professional judgment of the Dental Healthcare
Professional, this product should not be used.
be operated as an open water system (e.g. connected
to a public water system). A Dental Healthcare
Professional should disconnect the system from the
central water source. The Cavitron DualSelect system
can be attached to this unit and operated as a closed
system until the advisory is cancelled. When the
advisory is cancelled, flush all incoming waterlines
from the public water system (e.g. faucets, waterlines
and dental equipment) in accordance with the
manufacturer's instructions for a minimum of 5 minutes.
an antimicrobial such as Chlorhexidine Gluconate 0.12%.
Rinsing with an antimicrobial reduces the chance of
infection and reduces the number of microorganisms
released in the form of aerosols during treatment.