the quantity of smoke and odours being produced under the hood. When
the function is active, BL6 becomes active.Each time that the motor
changes speed, either automatically or forced by the user, BL6 lighting
blinking for a few seconds.
30h filter ALARM: After 30 hours of operation, an alarm switches on to
signal the need for anti-grease filter cleaning.The filter alarm, when active,
is displayed for 30 sec each time the motor is deactivated:BL6 remains
ON.During this period, it is possible to reset the alarm by pressing the TC6
button for longer than a second.
120h filter ALARM: After 120 hours of operation, an alarm switches on to
signal the need for active carbon filter (optional) replacement.The filter
alarm, when active, is displayed for 30 sec each time the motor is
deactivated:BL6 lighting blinking.During this period, it is possible to reset the
alarm by pressing the TC6 button for longer than a second.
Buttons TC5 + TC6 (ASC sensitivity): ASC odour sensor sensitivity can be
varied on 4 different levels as needed by pressing buttons TC5 and TCS
simultaneously for more than 1 second.The motor must be OFF and
automatic function NOT active.When sensitivity setting function is
activated:all BL switch OFF (no display) then BL6 activates FIX.After 1
second, the BL2-BL5 LEDs will show the set sensitivity value, BL2 for lower
sensitivity up to BL5 which indicates higher sensitivity. You can set a
different value using corresponding keys TC2, TC3, TC4 or TC5. To save
the new sensitivity, press TC6 or wait until the function deactivates
automatically.
It can be varied on your keyboard (for cleaning) with a long press of the
buttons TC1 and TC6 simultaneously. When the cleaning mode is active,
the keys TC1 and TC6 remain lit. To exit cleaning is necessary to activate
the buttons again TC1 and TC6 pressed simultaneously (long), or wait for 5
minutes.
Work Time Limit: if the hood is left on (lights and/or motor), after 10 hours
in the absence of commands from the user, it will automatically switch to
OFF condition with all services switched off.
Buzzer: the Buzzer emits a "beep" each time that a command is set from
the keyboard or remote control (optional).
Controls of Fig. 49
Key A: light switch;- position 0: light off;- position 1: light on.
Key B: motor switch; - position 0: motor off; - position 1-2-3: motor first,
second and thrid speed motor on.
MAINTENANCE
! Before cleaning or maintenance cut the power.
Cleaning the hood
WHEN TO CLEAN IT: clean it at least every 2 months to prevent the risk
of fire.
EXTERNAL CLEANING: use a cloth moistened in lukewarm water and
neutral detergent (for painted hoods); use specific products for steel,
copper or brass hoods.
INTERNAL CLEANING: use a cloth (or brush) soaked in denatured ethyl
alcohol.
WHAT NOT TO DO: do not use abrasive or corrosive products (e.g. metal
sponges, brushes, too hard brushes, very aggressive detergents, etc.)
Cleaning the grease filters
WHEN TO CLEAN IT: clean it at least every 2 months to prevent the risk
of fire, in according to use.
HOW TO REMOVE THE FILTERS: push the catch near the handle towards
the rear of the hood and pull the filter downwards
HOW TO CLEAN THE FILTERS: hand wash or in the dishwasher using a
neutral detergent. If washing in the dishwasher, possible discoloration of the
filters does not in any way compromise their functioning.
Replacing the charcoal filter
(for filtering version only)
WHEN TO REPLACE IT: replace it at least every 6 months, in according to
use.
HOW TO REMOVE IT: If using the hood in the filtering version, the
charcoal filter will have to be replaced. To switch off, pull the latch inward
and rotate the filter downwards.
Lighting
- Replace with light bulbs of the same type.
- If the light spot is damaged, it must be replaced only by the
manufacturer, its service agent or similarly qualified persons in order to
avoid a hazard.