7
8
9
1
3
2
12
English
Four-Hole Models only
Install the pin on the diverter.
Press the guide bushing firmly into place.
The hole in the pin should be clearly visible
through the slot in the guide bushing.
Lubricate the diverter o-rings using white plumbers
grease.
Press the diverter assembly firmly into the spout
tee until it is fully seated.
Firmly press the spout over the diverter.
3 mm
Tighten the screw using a 3 mm Allen wrench.
Install the diverter rod. The threaded end of the
diverter rod must go into the hole in the pin.
Do not overtighten the screw.
Overtightening the screw will
deform the o-rings, causing a leak.