TECHNICAL DATA
Dust Extraction
Production code
Battery voltage
Power input
Power consumption
Air delivery rate
Underpressure
Capacity
Filter type
Weight according EPTA-Procedure 01/2014 (Li-Ion 2,0 Ah ... 12,0 Ah)
Suction hose diameter
Recommended Ambient Operating Temperature
Recommended battery types
GB
Recommended charger
Noise information
Measured values determined according to ISO 4871. Typically, the A-weighted noise levels of the tool are:
Sound pressure level LpA (Uncertainty K=2dB(A))
Sound power level LWA (Uncertainty K=2dB(A))
Wear ear protectors!
Vibration information according to EN 60335-2-69
Total vibration values (vector sum in the three axes) determined according to ISO 5349.
Vibration emission value a
Uncertainty K=
WARNING! Read the instruction manual carefully
before using the appliance. Read all safety warnings and
all instructions.
Failure to follow the warnings and instructions may result in
electric shock, fire and/or serious injury.
WARNING: Operators shall be adequately instructed on the
use of these machines.
Save all warnings and instructions for future reference.
SAFETY WARNINGS DUST EXTRACTION
This machine is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge. Children
should be supervised to ensure that they do not play with
the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
This appliance may only be operated under supervision.
Fire and explosion hazard!
Never suck up into the machine any inflammable or explosive
solvents, or liquids like petrol, oil, alcohol, thinners, or small
particles (such as metal filings or ash) that may be hotter than 60°C
- otherwise there is danger of explosion or fire!
You are not allowed to use the appliance in the vicinity of inflam-
mable gases or substances.
Do not point the nozzle, hose or tube at people or animals.
Keep hair, loose clothing, fingers and all parts of the body away
from openings and moving parts. Do not put any objects into
English
12
h
openings or use with opening blocked. Keep openings free of dust,
lint, hair, and anything else that could reduce the flow of air.
WARNING! To reduce the risk of fire, personal injury, and product
damage due to a short circuit, never immerse your tool, battery
pack or charger in fluid or allow a fluid to flow inside them.
Corrosive or conductive fluids, such as seawater, certain industrial
chemicals, and bleach or bleach containing products, etc., Can
cause a short circuit.
Never break open battery packs and chargers and store only in dry
rooms. Keep dry at all times.
Use only System M18 chargers for charging System M18 battery
packs. Do not use battery packs from other systems.
Before starting work, the operating staff must be informed on and
trained within:
• use of the machine
• risks associated with the material to be picked up
• safe disposal of the picked up material
SPECIFIED CONDITIONS OF USE
This mobile dust extractor is designed, developed and rigorously
tested to function efficiently and safely when properly maintained
and used in accordance with the following instructions.
The vacuum cleaners described in this operating manual are
suitable for
• commercial use, e.g. in hotels, schools, hospitals, factories,
shops, offices and rental businesses.
• industrial use, such as e.g. plants, construction sites and
workshops.
M18 FBPV
4693 26 01...
... 000001-999999
18 V
25 A
380 W
1557 l/min
93 m
/h
3
18,9 kPa
189 mbar
3,8 l
HEPA H13
8,43 kg ... 9,53 kg
36 mm
-18°C ... +50°C
M18B...
M18HB...
M12-18...
M1418 C6
65 dB (A)
76 dB (A)
0,15 m/s
2
0,05 m/s
2