Technical Data - Pentair Jung Pumpen HEBEFIX EXTRA Instructions De Service

Masquer les pouces Voir aussi pour HEBEFIX EXTRA:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
of the hose clamp by hand. Check that
these components work by moving the
float switch up and down by hand. Press
the lid down onto the tank and hand
tighten the screws in the brackets in a
crosswise order. To prevent a collision
between the cable and the movable
parts in the tank, draw the cable out of
the tank as far as possible and securely
tighten the cable gland.

TECHNICAL DATA

Weight 6.2 kg
Pressure branch DN 32
Motor power P1 0.3 kW
Motor power P2 0.2 kW
Voltage 1/N/PEx230 V
Frequency 50 Hz
Rated current 1.2 A
Type of enclosure Plug unit IP 20
Control voltage for alarm circuit 12 V DC
(SELV)
Performance
H
 1
 2
 3
[m]
Q [m³/h]
 5,0  4,5  3,5  2,5  1,5
10
 4
 5
JUNG PUMPEN GmbH - Industriestr. 4-6 33803 Steinhagen, Germany
460.12.1405
EN 12050-2:2001
Lifting plant for faecal-free wastewater DN 32
HEBEFIX PLUS (JP44544)
HEBEFIX EXTRA (JP45757)
Collecting and automatically lifting faecal-free waste water above the
backflow level in buildings and sites
REACTION TO FIRE
WATERTIGHTNESS
EFFECTIVENESS (LIFTING EFFECTIVENESS)
- Pumping of solids
- Pipe connections
- Ventilation
- Minimum flow velocity
- Minimum free passage of the plant
- Minimum useful volume
MECHANICAL RESISTANCE
- Load bearing capacity and structural stability of collec-
tion tank for use outside buildings
- Structural stability of collection tank for use inside buil-
dings
NOISE LEVEL
DURABILITY
- of structural stability
- of lifting effectiveness
- of mechanical resistance
DANGEROUS SUBSTANCES
0197
13
NPD
Pass
Pass
Pass
Pass
Pass
Pass
Pass
NPD
Pass
≤ 70 dB(A)
Pass
Pass
Pass
NPD

Publicité

Table des Matières
loading

Table des Matières