Product Inspection - Flotec FP5712 Notice D'utilisation

Masquer les pouces Voir aussi pour FP5712:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

Product Inspection

The high pressure booster pump has been carefully
inspected and packaged to assure safe delivery. Inspect
the pump and fittings and report to the carrier any items
which are damaged or missing.
TABLE I - DISCHARGE PRESSURE
GPM
HP
10
1/2
10
3/4
10
1
*For total discharge pressure, add this pressure to suction pipe
pressure . For example, a 1 HP pump taking suction from an
80 psi water service line will produce 188 + 80 = 268 psi total
discharge pressure at 0 GPM flow. If suction pressure drops to 50
psi, discharge pressure will drop to 238 psi at 0 GPM flow.
Installation
The pump is designed to boost city water pressure or
water pressure from a private water system. Use this
high pressure stream to wash down milk parlors, barns,
garages and driveways, or for fire protection.
The pump is portable with a convenient carrying handle.
If an existing pressure water system is to be used as a
water supply, it can be connected with available fittings
and 3/4" or 1" high pressure hose to the pump inlet. If
pump is permanently mounted on wall, use a 3/4" or 1"
pipe or heavy-duty hose for suction line.
Risk of explosion . Do not ground to a gas
supply line. Pump body may explode if pressure exceeds
rated limits. Maximum inlet pressure is 80 PSI. Maximum
discharge pressure is 315 PSI. Warranty is void if these
pressure limits are exceeded.
For parts or assistance, call Flotec Customer Service at
Discharge
Discharge
No . of
PRessure
Pressure PSI
Stages
PSI at Rated
at No Flow*
Flow*
6
74
113
8
97
147
10
134
188
High Pressure Booster Pump
Installation Instructions
These instructions cover high pressure booster pump
installations as shown below:
From pressurized
house service
Figure 1 – Connection to house service.
Water tank
or reservoir
Figure 2 – Connection to water reservoir.
Priming Plug
Tee
Water Supply
Foot Valve
Figure 3 – Cistern or shallow well installation.
800-365-6832
Suction
Discharge
1208 0894
Suction
Discharge
1207 0894
90 Elbow
Male Pipe to Male Hose Adapter
Female Hose Connection
High Pressure
15 Feet
Hose
Maximum
Male Hose
Connection
Gun Nozzle
Weeping Type ONLY
1210 0894