7.7.1.2 Pump Wiring
The motor cables of the pump have a marking to allow
correct wiring. Connect the wires using this sequence:
1:
Motor cable L1
2:
Motor cable L2
3:
Motor cable L3
:
GND
If necessary, interchange any two phases to reverse direc-
tion. Refer to chapter "8 Pump Installation" on page 36
for detailed pump installation instructions.
Controller Installation
27