SCHÉMa dE RaCCORdEMENt
CS 106 400-440-480V 2AC
CHECK IF INPUT ON
TRANSFORMER ARE SET
FOR CORRECT INPUT
CSII 106 400-440-480V 2AC HE1
CS 110 400-440-480V 2AC
CHECK IF INPUT ON TRANSFORMER ARE
SET FOR CORRECT INPUT VOLTAGE.
CHECK IF HEATING ELEMENTS ARE
CORRECT CONNECTED.
CSII 110 400-440-480V 3AC HE1
16 MaNUEl d'ENtREtIEN Et d'INStallatON COMbISlIM CPE
VOLTAGE.
VL1.4
VL1.4
Red
Red
HEATING ELEMENT
CONNECTION FOR:
440-480V 3AC
VL1.4
Red
VL1.4
Red
HEATING ELEMENT
CONNECTION FOR:
400/415V 3AC
Connection must
follow input voltage
K2.4
K2.2
VL1.2
VL1.1
Black
White
K2.4
K2.2
VL1.2
VL1.1
Black
White
Connection must
follow input voltage
T1
400V = 400
415V = 415
440V = 440
480V = 480
37000053.00
400V = 400
415V = 415
440V = 440
480V = 480
37000054.00