F 200/400:
Frost should be removed when it is more than 1/2 cm thick. The cabinet should be
completely defrosted about twice a year.
Procedure:
Disconnect power at the mains and place a bowl of hot water in the cabinet. Close the door
and wait half an hour. The defrosting might be accelerated by blowing hot air into the cabinet
with a hair dryer. The remaining frost can now be wiped off with a warm cloth.
Never use a sharp or pointed object, that may damage the freezer.
Illumination
Applies to models with lamp only (KG 200/400).
The lamp can be switched on or off by the switch on the light panel.
Replacement of fluorescent tube/starter
Switch off power to the cabinet.
Press the lower rear edge of the lamp panel and remove the lamp screen.
The fluorescent tube/starter can now be turned 90° and replaced by a new one.
Use a fluorescent tube type L 15 W / 20 cool white.
Use a fluorescent tube starter type 4-80 W, single 220-240 V.
Changing from right-hinged door to left-hinged door
The door can be changed from righthand-hinged to lefthand-hinged, or vice versa.
To do so, proceed as follows:
16