Installation Instructions
Trouble shooting
Warning:
For your safety, ensure the power is switched OFF before starting the troubleshooting
procedures
TROUBLE
1.No functions operate
Warning:
Some task are
only to be performed by a
qualified technician.
2. Remote LED/LCD no
display
3. Operates only at close
range
4. More than one fan
operates interference at
same area.
Technical information
Transmitter (Remote):
Model No.: UC7216T
Rated Voltage: 2 X 1.5V AAA battery
Frequency: 433.92MHz
Operating range: approx. 20-30 feet.
7 | P a g e
PROBABLE CAUSES
Main power not restored
Wall switch power to the fan
remote is OFF
Receiver wiring incorrect
Transmitter and receiver DIP
switches do not match
The remote is too far from the
receiver
Battery too weak
Batteries at wrong polarity
The contacts in battery
compartment are corroded or bent.
Poor contact with batteries.
Signal blocked from reaching
receiver
Batteries too weak
RF interference
SUGGESTED REMEDY
Replace fuse. Turn ON circuit breaker. Turn
Switch wall switch ON, to power the remote
Verify wiring connections according to label
and wiring diagram
Set transmitter and receiver to same DIP
Move closer to receiver
Replace with all new batteries. Do not mix
the old and new batteries
Reinstall the batteries at right polarity
Clean corroded contacts.
Bend contacts back to their correct position
Roll the batteries to get them to sit in the
compartment, or replace with other brand
Extend antenna out from canopy, or move it
for better reception
Replace with all new batteries. Do not mix
the old and new batteries
Change DIP switch settings to a different
code. Each pair of transmitter and receiver
must have unique DIP switch code
Receiver (controller):
Model No.: UC7076RY
Rated Voltage: 230-240VAC 50/60Hz,
NON-DIMMING
Max. Motor load 0.5A, Ceiling Fan Only
Max. Incandescent/Halogen load 300W
Max. Fluorescent globe & ballast load 100VA
Max. LED driver load 100VA
ON wall switch
switch setting
batteries