FLASHING
4 - 5
LIGHT
6 - 9
OPEN/CLOSE
7 - 9
PEDESTRIAN
8 - 9
STOP
SENSITIVE
10 - 11
EDGE
10 - 12
PHOTOCELLS
RX
13 - 14
PHOTOCELLS
TX
13 - 15
PHOTOCELL
GATE OPEN
16 - 17
LED
2
RADIO
nd
18 - 19
CHANNEL
20 - 21
AERIAL
LIMIT
M1
SWITCH
M2
ENCODER
FS1 - FS2
CAPACITOR
230V AC
M3
MOTOR
FLASHING LIGHT output 230 Vac 50 W max. The signal is
already modulated for direct use. The flashing frequency during
closing is double. 4= 230 Vac, 5= 0 Vac;
OPEN/CLOSE pushbutton input (Normally Open contact);
PEDESTRIAN pushbutton input (Normally Open contact);
STOP pushbutton input (Normally Closed contact);
SENSITIVE EDGE input (resistive sensitive edge or fixed safety
edge); Works only when the gate is opening; temporarily stops
the gate and partially closes it by about 20 cm in order to allow
the obstacle to be removed. (10=Common);
NOTE: if a resistive sensitive edge is connected, set dip-
switch no. 12 to ON;
If a fixed safety edge with NC contact is connected, set dip-
switch no. 12 to OFF;
input for PHOTOCELLS OR SAFETY DEVICES active during
closure (Normally Closed contact); They stop the gate during
closing and totally reopen it; they temporarily stop the gate
during opening in order to allow the obstacle to be removed (if
dip switch n° 3 set to ON), (10= Common).
one safety device, connect all the NC contacts IN SERIES.
Note: the photocell transmitter must always be supplied
by terminals no. 13 - 15, since the safety system test
(phototest) is carried out on it. To override the testing of
the safety system, or when the photocells are not used, set
dip-switch no. 6 to OFF. If the phototest is not successful,
the control unit will not operate.
24 Vac 10 W output to POWER THE RXs AND ANY OTHER
TXs OF PHOTOCELLS THAT ARE PRESENT, EXTERNAL
RECEIVERS, etc.; connect a max. of 3 pair of photocells.
13= 0 Vac, 14= 24 Vac;
24 Vac 10 W POWER output for PHOTOCELL TX (only the one
that performs the Phototest) max. no. 1 photocell transmitter.
13= 0 Vac, 15= 24 Vac;
GATE OPEN LED output 24 Vac - max. 3 W; during opening of
the gate the warning light flashes slowly, when the gate is open
it remains steadily illuminated and during closure it flashes
twice as fast. 16= 0 Vac, 17= 24 Vac;
2nd RADIO CHANNEL output (its operation depends on dip-
switches nos. 7 - 8) to be used for opening/closing another
gate, for controlling garden lights or for the "ZONE LIGHTING"
function;
Warning: to connect other devices to the 2nd Radio Chan-
nel (area lighting, pumps, etc.), use an additional auxiliary
relay.
433,92 MHz built-in RX antenna input;
20= EARTH, 21= SIGNAL;
quick coupling for LIMIT SWITCH connection (Normally Closed
contacts). Orange= ClosureLimitSwitch (CLS),
red= OpeningLimitSwitch (OLS), grey= Common (COM);
quick coupling for ENCODER connection. Blue= 0 Vdc (GND),
brown= 5 Vdc (+5V), white= ENCODER SIGNAL (ENC);
faston for motor start-up CAPACITOR connection;
quick coupling for 230 Vac single-phase MOTOR connection
common= BLUE (M-COM); closure= BROWN (M-CL);
opening= BLACK (M-OP).
K580M