Fault
Cause
Display reads
Temperature sensor or Duomat
"F01 - F04"
defective
Display blank
Connector of connecting cable not
inserted correctly
Controller defective
Note: In the event of a technical defect, the Duomat will shut down the connected heating systems.
The corresponding error message will appear on the display. In this case, send in the Duomat to the
DENNERLE after-sales service.
11 Cleaning the surfaces of the Duomat
Use a moist cloth and a mild detergent.
Do not use any aggressive detergents or solvents!
12 Technical data
Mains voltage/mains frequency:
230 V~ / 50 Hz
Wattage:
2 W + connected heating systems (max. 1,200 W)
Outputs for heating systems:
Bed heating 230 V~,
max. 400 W / T2A
Water heating 230 V~,
max. 800 W / T4A
Length of mains lead:
3 m
Length of connecting lead:
3 m
Length of sensor cable:
3 m
Connection for connecting cable:
SUB-D 9polig
Measuring range:
5-50 °C
Setting range:
18-34 °C
Splash-proof in accordance with IPX4
30
Remedy
Send Duomat in to DENNERLE
after-sales service for inspection.
Connect correctly and secure with
screws
Send Duomat in to DENNERLE
after-sales service.
DENNERLE
13 Spare parts
3042 2 Longlife suction clips, black
1626 2 fuses for bed heating, 2 A
1627 2 fuses for water heating, 4 A
14 Guarantee conditions
Guarantee period: 36 months
Defective parts will be replaced or repaired free of charge during the guarantee period, on condi-
tion that the equipment is used in the proper manner for the intended purpose and the guarantee
card and receipt of purchase are sent to DENNERLE.
During the guarantee period, the device may only be opened by DENNERLE's after sales personel,
otherwise the guarantee coverage will lapse.
No claims shall be assertible beyond the value of the device, e.g. for damage to fish or plants.
Duomat Evolution DeLuxe