Télécharger Imprimer la page

RIDGID R4517 Manuel D'utilisation page 28

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
 Pull out the stop pin and rotate the gauge until the desired
angle is reached on the scale.
 Retighten the lock knob by turning it clockwise.
TO USE THE SLIDING TABLE EXTENSION
See Figure 32.
Increase the length of the saw table by using the table
extension.
 Remove the rip fence.
 Unlock the sliding table extension by lifting the table
extension lock lever.
 Slide the table extension to the desired width.
NOTE: Use the scale on the front rail when a specific
width is desired.
 Once the extension table is set to the desired width,
relock the lever by pushing the lever back towards the
saw base.
HEELING (PARALLELING) THE BLADE TO THE
MITER GAUGE GROOVE
See Figures 33 - 35.
WARNING:
The blade must be square so the wood does not
bind resulting in kickback. Failure to do so could
result in serious personal injury.
Do not loosen any bolts for this adjustment until you have
checked with a square and made test cuts to be sure adjust-
ments are necessary. Once the bolts are loosened, these
items must be reset.
 Unplug the saw.
 Remove the blade guard and anti-kickback pawls. Raise
the blade by turning the height/bevel adjusting handwheel.
 Mark beside one of the blade teeth at the front of the
blade. Place the body of a combination square against
the miter gauge groove as shown in figure 34. Measure
the distance from the blade tooth to the right miter gauge
groove.
 Turn the blade so the marked tooth is at the back.
 Move the combination square to the rear and again mea-
sure the distance from the blade tooth to the right miter
gauge groove. If the distances are the same, the blade
and the miter gauge groove are parallel.
If the distances are different:
 Place riving knife in "down" position.
 Loosen adjusting bolts (1) and (3).
NOTE: The adjusting bolts are located under the saw
table in the back of the saw.
 Turn adjusting bolt (2) left or right until the blade is parallel
to the miter gauge slot.
 Retighten adjusting bolts (1) and (3).
SLIDING TABLE
EXTENSION
SCALE
ADJUSTING BOLTS (3)
28 − English
LOCK LEVER
(1)
COMBINATION
SQUARE
TABLE
EXTENSION
Fig. 32
(3)
(2)
Fig. 33
MITER
GAUGE
GROOVE
Fig. 34