17. Fault Correction
Fault
Water does not flow
Flow duration too
short or too long
Water flow too weak
Water is too cold
If you are unable to correct a fault or if the fault is not described in the fault correction
section, please inform our customer service department!
18. Replacement Parts
Designation
1 Solenoid valve 24V . . . . . . . . . . . . 2000101328
2 Aerator with special tool. . . . . . . . . 2000105959
3 Head piece, complete
with aerator. . . . . . . . . . . . . . . . 2000105485
4 Shower bracket 165 mm . . . . . . . . 2000109150
5 Flow rate regulator (VPE 10 St.)
0,10 l/s . . . . . . . . . . . . . . . . . . . 2000104701
6 Installation kit comprising:
O-rings
Grub screws . . . . . . . . . . . . . . . 2000104797
7 Sensor module 2
without mount . . . . . . . . . . . . . . 85-100-17.116
8
Cause
– Voltage supply interrupted
– Water supply closed
– Sensor module faulty
– Flow duration setting incorrect
– Water inflow not fully opened
– Grit filter is clogged
– Supply pressure too low
– Hot water is turned off
– Grit filter is clogged
– Hot water supply pressure too low
– Hot water temperature too low
Order No.
Accessories
8 Power supply (12 W) . . . . . . . . . . .2000100375
CHROMOL 0.5 l stainless steel
polish . . . . . . . . . . . . . . . . . . . .2000105091
Complete stainless steel care set
CHROMOL 0.5 l
Abrasive sponge, coarse
Abrasive sponge, fine . . . . . . . .2000109019
*) When placing an order, please specify the fittings-ID!
The fittings-ID is located on the side of the electronic
module.
Remedy
➯ Restore it
➯ Open it
➯ Replace it
➯ Adjust it
➯ Open it
➯ Clean it
➯ Check it
➯ Open it
➯ Replace it
➯ Check it
➯ Increase it
Order No.