13. Setting the Range
Flow range can be adjusted only with an ECC2 function controller via the Web
application.
14. Maintenance and Servicing
Depending on the quality of the water, the local conditions and the rules and
regulations applicable on site, the fitting must be maintained and serviced at regular
intervals.
Properly use suitable cleaning agents that are not harmful to the fittings and rinse
with water after use. High-pressure cleaners must not be used for cleaning.
Follow the cleaning instructions for stainless steel.
15. Replacing the Flow Rate Regulator
15.1 Loosen the grub screw in the outlet using an Allen key.
15.2 Pull the wall arm with the head piece from the connection spigot.
15.3 Remove the safety ring with the appropriate pliers for the inner safety rings.
15.4 Pull out the flow rate controller with flat nose pliers.
☞
Important!
Ensure correct installation orientation of the flow rate regulator. The brace must face
in the direction of the outlet.
15.5 Insert the flow rate regulator and secure with the circlip.
a: Brace
b: Flow direction
15.6 Slide the wall arm with the head piece onto the connection spigot.
15.7 Tighten the grub screw using a hollow hexagon wrench.
16. Replacing an Aerator
16.1 Use the special tool (e) to loosen the complete aerator.
16.2 Remove the complete aerator from the head piece (a).
16.3 Remove the seal (b).
16.4 Remove the sleeve (c).
16.5 Replace the aerator (d).
16.6 Reassemble in the reverse order.