SYSTEM PROBLEMS
EN
PROBLEMS WITH MANUAL RESET
These problems are reset by the user: by pressing key
p
the fault is present keys
OVERLOAD
SPEED
0M/M
UP ALLARM
SPEED
0M/M
NO SENSOR
SPEED
0M/M
SENSOR FAILUR
SPEED
0M/M
CONFIRMATION MESSAGES
Confirmation messages that may appear on the state line are shown below.
STOP
SPEED
0M/M
MEMORY STORED
SPEED
0M/M
LOCKED
SPEED
0M/M
34
q
,
(UP, DOWN) are disabled.
Overload
This fault is signaled when the instrument detects at short circuit or overload at the in-
strument's output.
Check wiring of signals UP and DOWN and absorption of the points of use connected to
the output of the instrument.
If there is a fault, keys
Up alarm
This fault is displayed if the length of the chain is less than the value set on the FUNC-
TIONS\UP ALARM menu.
No sensor
This fault is displayed if the laps sensor does not detect the gypsy movement within four
seconds (for a longer time if auto free fall management is activated) when key
(UP or DOWN ) of the chain counter or other switches are pressed.
Check the distance between the magnet and sensor, operation of the laps sensor and
the wiring/connections.
Sensor failure
This fault is displayed if the chain counter detects a short circuit in the sensor for more
than four seconds (for a longer time if auto free fall management is activated) when key
p
q
, or
(UP or DOWN ) of the chain counter or other switches are pressed.
Check operation of the laps sensor and the wiring/connections.
Stop
When no commands are sent to the windlass, the following window is displayed:
Memory stored
As soon as four seconds elapsed from the last operation was completed (up, down, au-
tomatic down, free fall), the chain counter stores the length of the lowered chain in the
EEPROM memory.
The window shown below is displayed while the data are being saved:
Locked Controls
Once the time set in the LOCKED KEYS parameter has elapsed, the instrument will inhibit
the functionality of the
no effect. Pressing the
(UP and DOWN) keys.
=
(SELECT) or turn off the chain counter and turn it back on. If
p
q
,
(UP, DOWN) are inoperative.
p
q
and
and (UP and DOWN) keys; pressing these keys will have
=
key (SELECT) will reactivate the functionality of the
p
q
, or
p
q
and
CHC1203 IT EN FR - REV001A