Victron energy BlueSolar MPPT 100/15 Manuel page 10

Masquer les pouces Voir aussi pour BlueSolar MPPT 100/15:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
5 Specifications
BlueSolar charge controller
Battery voltage
Maximum battery current
Maximum PV power, 12V 1a,b)
Maximum PV power, 24V 1a,b)
Automatic load disconnect
Maximum PV open circuit voltage
Peak efficiency
Self consumption
Charge voltage 'absorption'
Charge voltage 'float'
Charge algorithm
Temperature compensation
Continuous/peak load current
Low voltage load disconnect
Low voltage load reconnect
Protection
Operating temperature
Humidity
Maximum altitude
Environmental condition
Pollution degree
Data communication port
Colour
Power terminals
Protection category
Weight
Dimensions (h x w x d)
Safety
1a) If more PV power is connected, the controller will limit input power to
200W resp. 400W.
1b) PV voltage must exceed Vbat + 5V for the controller to start.
Thereafter minimum PV voltage is Vbat + 1V.
8
12/24 V Auto Select
200W (MPPT range 15V to 100V)
400W (MPPT range 30V to 100V)
Yes, maximum load 15A
14,4V / 28,8V
13,8V / 27,6V
multi-stage adaptive
-16mV / °C resp. -32mV / °C
11,1V / 22,2V or 11,8V / 23,6V
or BatteryLife algorithm
13,1V / 26,2V or 14V / 28V
or BatteryLife algorithm
Battery reverse polarity (fuse)
Output short circuit / Over temperature
-30 to +60°C (full rated output up to 40°C)
100%, non-condensing
Indoor, unconditioned
See the data communication white paper on our website
ENCLOSURE
Blue (RAL 5012)
6mm² / AWG10
IP43 (electronic components)
IP22 (connection area)
100 x 113 x 47mm
STANDARDS
EN/IEC 62109
MPPT 100/15
15A
100V
98%
10mA
(adjustable)
(adjustable)
15A / 50A
2000m
PD3
VE.Direct
0,4kg

Publicité

Table des Matières