PROBLEM
POSSIBLE CAUSES
The
regulator does
The regulator or its internal parts
not regulate
are dirty or damaged.
the pressure.
There is a leak at one of the
The tank drain valve is open.
The pressure
The air intake is restricted.
is low, or there
is not enough
Prolonged excessive use of air.D
air.
There is a hole in the air hose.
The tank leaks.
The valve is leaking.
There is condensation in the air
There is
tank caused by a high level of
moisture in the
atmospheric humidity or because
discharge air.
the air compressor has not been
running long enough.
The ventilation is inadequate.
The
compressor
Cooling surfaces are dirty.
overheats.
The valve is leaking.
English
SOLUTIONS
Replace the regulator.
threads). Do not overtighten.
Close the drain valve.
Clean the ventilation openings on the motor's
enclosure.
ecrease the amount of air used.
Check the air hose and replace it if necessary.
Replace the tank Immediately. Do not attempt
to repair it.
Check for worn parts, and replace them if
necessary.
Drain the air tank after each use. Drain the air
tank more often in humid weather and use an
Relocate the compressor to an area with cool,
dry and well-circulated air.
Clean all cooling surfaces on the pump and the
motor thoroughly.
Replace worn parts and reassemble using new
12